USER MANUAL
9
The unit is supplied with a power plug appropriate to its voltage and
destination. Should any other connections be required they must be
carried out with the following configuration.
DMX-512 connection between fixtures
The fixture is equipped with 2-pin XLR sockets for DMX input and output. The
sockets are wired in parallel. Only use a shielded twisted-pair cable designed for
3-pin XLR-plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR-connection
Caution: At the laser fixture, the DMX-cable has to terminate with a
terminator. Solder a 120 Ohm resistor between Signal (-) and
Signal (+) into a 3-pin XLR-plug and plug and plug it in the
DMX-output of the last fixture.
Cable(EU)
Cable(US)
Pin
International
Brown Black Live
L
Light blue
White
Neutral
N
Yellow/Green
Green Earth
Summary of Contents for LSX-300SRGB