Battery
installation
1. Loosen the screws on the battery cover.
2.
Open the battery cover and put batteries into the battery
case according to the polarity shown in the battery slot.
Replace the battery cover and tighten the screw.
Initial Set up
In order to ensure the measurement accuracy, it is recommended
that you check the accuracy before operating.
After fitting the batteries, place on a flat horizontal surface with the
LCD display facing you and press the power button to turn the
EL30 on. Record the angle value (A) on the display.
Rotate the EL30 180° with the screen facing away from you and
record the value (B).
If A, B angle value margin exceed 0.2 degree, it is necessary to
calibrate the horizontal accuracy.
Also follow above procedure in vertical position to check vertical
accuracy
Calibration
1. Select a flat and horizontal platform as a reference
surface
2. Press the power button to turn the unit on
3. Press and hold the ZERO button until -0- is displayed on
the LCD screen. Wait 3 seconds, press the ZERO button
again the LCD will now display -1-
4. Turn the unit 180 degrees, keeping the unit on the same
horizontal platform, and wait for 3 second, then press
ZERO, the LCD will display -2-, and then will display angle
value. Horizontal calibration is now complete.
Note: all the above operation should be operated on the same
position of the same plane.
To calibrate vertical plane, repeat above procedure on vertical
plane.
Technical
Specifications
Measuring Accuracy
±0.1°
Working Range
0°- 360°
Display Mode
5 x Display modes
Resolution
0.1°
Laser wavelength
650nm / Class 2
Laser indication range
±0.3mm/m
Power
3 x AAA Batteries
Working temperature
-10°C to +45°C
Size
305 x 60x 32mm
Weight
670g with batteries