Functions

 

On/Off Button  
Mode Select 
Calibrate 
Sound On/Off 
Hold 

Press to turn the EL20 on or off 
Select to display ° or % 
Long Press to enter calibrate mode 
Short press to turn sound on or off 
Press to freeze the display 

 

Battery 
installation 

1.  Loosen the screws on the battery cover. 
2.  Open the battery cover and put batteries into the 

battery case according to the polarity shown in the 
battery slot. Replace the battery cover and tighten 
the screw. 

 

 

Initial Set up

 

In order to ensure the measurement accuracy, it is 
recommended that you check the accuracy before 
operating. 

 

After fitting the batteries, place on a flat horizontal surface 
with the LCD display facing you and press the power button 
to turn the EL20 on.  Record the angle value (A) on the 
display. 

 

Rotate the EL20 180° with the screen facing away from you 
and record the value (B). 

 

If A, B angle value margin exceed 0.2 degree, it is 
necessary to calibrate the horizontal accuracy. 

 

Also follow above procedure in vertical position to check 
vertical accuracy 

 

 

Calibration 

1.  Select a flat and horizontal platform as a reference 

surface 

2.  Press the power button to turn the unit on  
3.  Press and hold the ZERO button until -0- is 

displayed on the LCD screen. Wait 3 seconds, 
press the ZERO button again the LCD will now 
display -1- 

4.  Turn the unit 180 degrees, keeping the unit on the 

same horizontal platform, and wait for 3 second, 
then press ZERO, the LCD will display -2-, and then 
will display angle value. Horizontal calibration is 
now complete. 

 

Note: all the above operation should be operated on the 
same position of the same plane.  

 

To calibrate vertical plane, repeat above procedure on 
vertical plane.

 

Summary of Contents for EL20

Page 1: ...play holding function Inclination direction indication Self calibrate able Components 1 x EL20 Digital Level 1 x Carry Pouch 1 x Instruction Manual Product Identification The model and serial number of your product are indicated on the product Please keep a these recorded in your manual and always refer to this information should you need to contact your Imex distributor Model number Serial number...

Page 2: ...or the product The person responsible for the product has the following duties To understand the safety instructions on the product and the instructions in the user manual To ensure that it is used in accordance with the instructions To be familiar with local regulations relating to safety and accident prevention To inform Imex immediately if the product and the application becomes unsafe To ensur...

Page 3: ... the angle value A on the display Rotate the EL20 180 with the screen facing away from you and record the value B If A B angle value margin exceed 0 2 degree it is necessary to calibrate the horizontal accuracy Also follow above procedure in vertical position to check vertical accuracy Calibration 1 Select a flat and horizontal platform as a reference surface 2 Press the power button to turn the u...

Page 4: ...operated and properly preserved any violent shock or falling will possibly result in to damage the instrument Keep the instrument clean Keep away from of wet and damp conditions Do not attempt to disassemble the unit as any unprofessional disassembly will result in damage to the instrument Take the batteries out when the instrument is not in use for long periods of time Version 05 English Copyrigh...

Reviews: