2. Directions of Use continued: 
 

2.4 Using Your Detector 

 

Detector 
Operation 

 

Power the detector on by pressing the power button. The speaker 
will beep once to indicating the unit is operating 

 

The LCD screen will display the battery level, detection mode and 
speaker display 

 

Press the Course/Fine button to switch between course or fine 
detection mode 

 

Move the detector into the path of the laser beam 

 

The  direction  of  the  arrows  on  the  LCD  screen  to  indicate  the 
position of the laser beam. The detector will emit a constant beep 
and  LCD  will  show  horizontal  line  once  the  level  position  is 
located 

 
 
3. Batteries 

General 

The E60 is supplied with 4x AA 1.5V Alkaline batteries 

 

The LR1 Receiver is supplied with 1 x 9V battery 

 

Battery Placement 

When  putting  battery  into  the  laser  unit,  please  ensure      

correct polarity of terminals.  

 

 
 
 
 
 
 
 
 

Summary of Contents for E60

Page 1: ...Quick Start Manual E60 ROTARY LASER LEVEL QUICK START INSTRUCTION MANUAL ...

Page 2: ...number of your E60 is indicated on the base of the laser level Please keep this recorded in your manual and always refer to this information should you need to contact your Imex distributor Serial number Validity of this manual This manual applies to the Imex E60 laser and contains instructions required to operate this laser at a basic level For more information www imexlasers com Table of content...

Page 3: ... Unit Rotary Laser Aperture Protective Lighthouse Power Indicator Tilt Warning Indicator Power On Off Tilt Warning Tripod Mount 1 2 LR1 Laser Detector Laser Sensor LCD Display Clamp Power On Off Speaker On Off Course Fine Detection Speaker ...

Page 4: ...as re levelled the laser head will begin to spin again emitting a level line Warning If the unit has been bumped or moved and the laser recommences spinning the instrument may not be at the original level position Please recheck you RL datum point 2 3 Tilt Warning System TWS Description of TWS Mode To prevent the possibility of the E60 giving a different reading than is expected due to a knock or ...

Page 5: ...between course or fine detection mode Move the detector into the path of the laser beam The direction of the arrows on the LCD screen to indicate the position of the laser beam The detector will emit a constant beep and LCD will show horizontal line once the level position is located 3 Batteries General The E60 is supplied with 4x AA 1 5V Alkaline batteries The LR1 Receiver is supplied with 1 x 9V...

Page 6: ...xis so that it is square to the wall Allow the E60 to self level completely and it will begin to rotate 3 Mark the position of the beam on the wall centre of the point 4 Very carefully rotate the laser on the tripod 180 and allow it to rotate and self level 5 Mark the position of the beam on the wall centre of the point if different from the original mark 6 Align the second axis so it is flat to t...

Page 7: ...emperatures of 10 C to 50 C After long periods of storage check the charge of the batteries Always clean the unit before storing Even if the unit is in regular use If the unit has been used in damp weather ensure it is dried prior to placing it back in its carry case It is important to keep the carry case dry to prevent any ingress of moisture 6 Laser Specification Specification Operating Range 40...

Page 8: ... 7 Copyright Imex Group International 2018 ...