Imex Ceramics UK,
15 Millbrook Industrial Estate, Sybron Way, Crowborough, East Sussex. TN6 3DU
www
.imexceramic.co.uk
Technical Helpline: 01
530 835598
1
ǃ
Maintenance of fill valve
Troubleshooting
1.The water level too high or too low
malfunction
solve way
2.Can not stop water
3.Fill water speed slow
4.Others questions
Adjust the water level
Wash the rubber and seal and filter
Wash filter, increase the water pressure
Pleases consult with a professional technician
2
ǃ
Maintenance for flush valve
malfunction
Troubleshooting
1.Can not flush water
reason
solve way
1.Leaking
The flush pole may be damaged
Replace the flush pole
The working water level too low
Adjust the working water level
The rubber seal can not seal water
The movement of flush valve is blocked
Replace the rubber seal
Wash the debris of flush valve
ķ$GMXVWWKHVPDOOIOXVKZDW
er volume
by adjust the small flush adjuster.
ĸ
Wash the debris out
by flushing and clean water.
sealed rubber
Ĺ7DNHRXWRIWKHVL
lica gel of flush
valve,clean or replace it.
small flush adjuster
ĺ7DNHRXWRIWKHVHDO
ed rubber of
flush valve.clean or replace it.
ķ
Turn the knob,adjust water level height.
Take off the filter tip and clean
Loosen the nut and clean or replace
the valve core and the silica gel of fill valve
ĸ
Wash the dirt
valve core
silica gel