background image

EN

79

EN

78

ATTENTION

It is recommended to always start the first hair removal session by setting 

the lowest power level (level 1).

If you feel no discomfort during the hair removal session with the power 

level set to the lowest, you can increase the power to level 2 at the next 

session, and so on for each subsequent session.

Do not increase the power level if you feel an abnormal discomfort during 

or after the treatment! (See “Possible side effects”).
Do not increase the power level during a hair removal session, even if no 

discomfort is felt: side effects can also arise some time after the session.

SKIN COLOUR SENSOR (5B)

Using the pulsed light epilation system on dark skin can cause adverse effects 

such as burns, blisters and changes in the colour of the skin (hyper or hypo-

pigmentation).

The appliance has a skin colour sensor (5B) that measures the tone of the 

skin in the area that is to be treated at the beginning of each session and 

occasionally during the session. 

If the skin colour sensor (5B) detects a complexion that is too dark for the 

treatment, the appliance stops emitting the light pulses automatically and the 

skin colour check LEDs (6A) start to flash.

If this occurs, try to use the appliance on another part of the body or contact 

the IMETEC service centre.

COVERING THE ENTIRE TREATMENT AREA

A precise technique must be followed during the session to make sure the entire 

treatment area is covered and dangerous overlapped pulses are prevented:

•  Imagine the treatment area is divided in rows.

•  Emit a light pulse proceeding in order, starting from one end of each row 

and continuing to the other end (from the bottom upwards or right to left, 

depending on the treatment area).

The area covered by the treatment surface (5A or 15A) leaves temporary marks 

on the skin due to the light pressure applied by the handpiece. 

These marks remain visible for a few moments and are useful to establish the 

subsequent pulse position.

ATTENTION

Do not overlap the pulses!

Do not treat the same section of skin more than once per hair removal session!

STOP USING THE APPLIANCE IMMEDIATELY if excessive heat or tingling 

is felt or blisters or small burns appear on the skin!

HOW TO PERFORM THE PATCH TEST

Since the skin tone and sensitivity varies from one body part to another, a 

patch test should be performed on each part of the body that is to be treated. 

•  First check the tone of your skin by comparing it to the table on the package 

and in the instruction manual. 

Summary of Contents for Bellissima Flash&Go Plus 120.000

Page 1: ...49 TYPE I6701 I6702 Istruzioni per l uso Instrucciones de uso Operating instructions Instru es para o uso Epilatore a luce Pulsata Depiladora con luz pulsada INTENSE PULSED LIGHT EPILATOR Sistema de d...

Page 2: ...e A Escala de tonalidades de la piel A Skin tone range A Escala de tonalidades da pele A Non usare su pelle naturalmente scura o abbronzata No la utilice para la piel naturalmente oscura o bronceada D...

Page 3: ...KSAPV0361200300D5 INPUT 100 240V 50 60Hz 71 99VA 0 9A OUTPUT 12V 3 0A MODEL KSAPV0361200300D5 INPUT 100 240V 50 60Hz 71 99VA 0 9A OUTPUT 12V 3 0A DATI TECNICI DATOS T CNICOS TECHNICAL DATA DADOS T CNI...

Page 4: ...sente manuale di istruzioni stato redatto in conformit alla norma europea EN 62079 ATTENZIONE Istruzioni e avvertenze per un impiego sicuro Prima di utilizzare l apparecchio leggere attentamente leist...

Page 5: ...esto apparecchio non pu essere utilizzato da persone di et inferiore a 16 anni pu essere usato da persone con capacit fisiche sensoriali o mentali ridotte o da persone inesperte solo se preventivament...

Page 6: ...domestico Qualsiasi altro utilizzo considerato non conforme e pertanto pericoloso Questo apparecchio non adatto per essere usato in presenza di misceleanesteticheinfiammabiliconariaoOssigenooOssidoNit...

Page 7: ...IDA AL MOMENTO DEL TRATTAMENTO In gravidanza o allattamento Se sei stata esposta al sole forte o a una macchina per abbronzatura artificiale nel corso degli ultimi 28 giorni Se hai un tatuaggio o un t...

Page 8: ...ttivo sul pigmento del pelo Quantit diverse di pigmento melanina sono presenti anche nel tessuto cutaneo circostante La quantit di pigmento presente nella pelle che si manifesta nella tonalit della pe...

Page 9: ...sulla pelle durante l uso dal livello pi basso al livello pi alto Le luci di indicazione livello di energia 12 indicano il livello di energia impostato Quando il livello di energia sale migliorano i...

Page 10: ...abbronzanti Per le due settimane successive ad ogni seduta di trattamento in caso di esposizione al sole proteggere la pelle trattata con una crema con filtro solare SPF 30 o superiore ATTENZIONE l us...

Page 11: ...nti Generalmente quando si formano cicatrici hanno la forma di una lesione piatta e bianca della pelle ipotrofica Tuttavia la cicatrice pu essere molto grande e rossa ipertrofica o grande e estesa olt...

Page 12: ...limentatore 5 Lampada 5A Superficie di trattamento 5B Sensore del colore della pelle 6 Luci di pronto all uso 6A Luci di controllo colore della pelle 7 Luce di errore guasto 8 Tasti impostazione livel...

Page 13: ...antenimento saltuarie La reazione individuale dipende dal tipo di peli e da fattori biologici che possono influenzare il ciclo di crescita dei peli Rispetto al programma di epilazione consigliato alcu...

Page 14: ...nizio di ogni seduta e di tanto in tanto nel corso della seduta Se il sensore del colore della pelle 5B rileva una carnagione troppo scura per l applicazione l apparecchio smette automaticamente di em...

Page 15: ...principio termico del trattamento non si deve superare la soglia massima che la propria pelle riesce a tollerare Questa soglia di norma alta per le pelli chiare e bassa per le pelli scure perch la pre...

Page 16: ...ndi dall emissione dell impulso precedente le luci di pronto all uso 6 si accendono nuovamente 14 Spostare la superficie di trattamento 5A o 15A su una nuova porzione di pelle Usare i segni di pressio...

Page 17: ...disostituzionedellalampada 13 lampeggia pi velocemente Quandogliimpulsidellalampada 5o15 sonoesauriti lalucedisostituzione della lampada 13 diventa fissa e non pi possibile emettere impulsi Per contin...

Page 18: ...e il tasto di accensione standby 10 Se il problema persiste contatta il Centro di Assistenza Clienti lMETEC OPPURE 5 Controlla la luce di errore guasto 7 se la luce accesa spegni l apparecchio e riacc...

Page 19: ...n del aparato a terceros entregue tambi n todos los documentos Si al leer este manual de instrucciones para el uso alguna de sus partes resultara dif cil de entender o si surgieran dudas antes de usar...

Page 20: ...rca de ba eras duchas fregaderos u otros recipientes que contienen agua Nunca sumerja el aparato en l quidos Despu s de sacar el aparato del embalaje controle que el suministro est completo conforme a...

Page 21: ...o roto No use el aparato si el revestimiento externo del aparato est rajado o roto No use el aparato si la l mpara 5 o 15 est da ada o si la superficie de tratamiento 5A o 15A est rajada agrietada o...

Page 22: ...o con cidos alfa hidr xidos AHA cidos hidr xidos BHA Retin A retinoides t picos o cido azelaico Si presenta condiciones cut neas anormales ocasionadas por diabetes por ejemplo u otras enfermedades sis...

Page 23: ...reciente al sol y o a l mparas bronceadoras Un uso de este tipo puede ocasionar quemaduras graves heridas ampollas variaciones en el color de la piel hiper o hipopigmentaci n La piel bronceada especi...

Page 24: ...has de color marr n oscuro o negro como pecas grandes manchas de nacimiento lunares o verrugas antes de usar el aparato Nunca use l quidos inflamables como alcohol productos que contengan alcohol incl...

Page 25: ...ilaci n con luz pulsada dom stica sea generalmente muy bien tolerada la mayor parte de los usuarios advierten una molestia leve durante el uso generalmente descrita como una leve sensaci n de calor o...

Page 26: ...riesgo posible despu s de una quemadura o herida ocasionada por el aparato Hematomas Muy raramente el uso de aparato puede ocasionar hematomas azul viol ceos que pueden durar de 5 a 10 d as A medida q...

Page 27: ...equerir de 18 a 24 meses En el curso de este intervalo de tiempo pueden ser necesarias varias sesiones para obtener una depilaci n permanente La eficacia de la depilaci n var a de una persona a otra d...

Page 28: ...icadoras izquierda y central est n encendidas de forma estable y la luz indicadora derecha parpadea Nivel 5 el m s alto las 3 luces indicadoras est n encendidas de forma estable ATENCI N Se recomienda...

Page 29: ...otra conviene realizar un patch test sobre cada zona del cuerpo a tratar Controle principalmente la tonalidad de su piel compar ndola con la tabla presente en el embalaje y en el manual de instruccion...

Page 30: ...te 3 5 segundos despu s de haber presionado la tecla de encendido standby 10 la luz de encendido 11 se enciende el aparato se configura autom ticamente en el nivel de energ a m s bajo 9 Realice el pri...

Page 31: ...asiado oscura Despu s de emitir un impulso presione la tecla de encendido standby 10 la luz de encendido 11 se apaga y la luz de standby 9 se enciende Extraiga la l mpara 5 del cabezal sujet ndola y t...

Page 32: ...alimentador 14 est conectado a una toma el ctrica en la pared Cuando se presiona la tecla de activaci n del impulso 3 no se emite una luz 1 Verifique que las luces de listo para usar 6 parpadeen para...

Page 33: ...de este manual de uso cuidado y mantenimiento del producto comporta la p rdida de la garant a del fabricante MI000937 0612 MMYY Tel 39 035 688 111 Fax 39 035 320 149 INTENSE PULSED LIGHT EPILATOR ins...

Page 34: ...the age of 16 and can only be used by persons with reduced physical sensorial or mental abilities or persons lacking experience if they have received prior instructions concerning its safe use and if...

Page 35: ...et or barefoot Do NOT pull the power cord or the appliance itself to remove the plug from the socket Do NOT expose the appliance to humidity or weather conditions rain sun Always disconnect the applia...

Page 36: ...psoriasis lesions open wounds or active infections such as herpes in the treatment area Wait for the affected area to heal before using the appliance If you have a history of keloid formation if you k...

Page 37: ...y type of pulsed light epilation is used Compare your complexion with the skin tone range A provided in this manual and or on the package of the product before using the appliance NATURALLY DARK SKIN...

Page 38: ...eatment at the lowest power level Only if you feel a little or no discomfort with the power level set to the lowest can you increase the power by one level at the next session and so on for each subse...

Page 39: ...gher ATTENTION treatment may cause a temporary change in pigmentation refer to Possible side effects POSSIBLE SIDE EFFECTS Side effects and complications associated with the appliance are rare when us...

Page 40: ...hypotrophic However the scar may also be big and red hypertrophic or big and beyond the wound itself keloid Subsequent aesthetic treatment may be required to improve the appearance of the scar Change...

Page 41: ...onnection 5 Lamp 5A Treatment surface 5B Skin colour sensor 6 Ready for use LEDs 6A Skin colour check LEDs 7 Error fault LED 8 Power level setting buttons 9 Stand by LED 10 Switch on stand by button 1...

Page 42: ...the type of hair and biological factors that may affect the growth cycle of hair Some people can react quicker or slower with regards to the recommended hair removal plan In any case a long lasting r...

Page 43: ...he skin colour check LEDs 6A start to flash If this occurs try to use the appliance on another part of the body or contact the IMETEC service centre COVERING THE ENTIRE TREATMENT AREA A precise techni...

Page 44: ...olerates with no discomfort whatsoever PREPARING THE AREAS THAT ARE TO BE TREATED The skin must be shaved clean dry with no make up anti perspirant or deodorant Moles birthmarks dark spots tattoos and...

Page 45: ...rocess starting from point 10 until the entire area to be treated is covered AFTER TREATMENT 16 Press the switch on stand by button 10 all the LEDs that are on go off and the stand by LED lights up 9...

Page 46: ...lacement LED 13 remains on and no further pulses can be emitted The lamp 5 or 15 must be replaced with an original one for the relative model in order to continue the treatment session Note do not use...

Page 47: ...m persists contact the IMETEC Customer Service Centre OR 5 Check the error fault LED 7 if the LED us on switch the appliance off and on again by pressing the switch on stand by button 10 twice If the...

Page 48: ...relho for cedido a terceiros entregue tamb m toda a documenta o Se durante a leitura deste manual de instru es de uso algumas partes n o forem suficientemente claras ou em caso de d vidas contacte a e...

Page 49: ...dor um conselho a respeito ATEN O N o utilizar o presente aparelho nas proximidades de cubas de banho duchas pias ou outros recipientes a conter gua Nuncamergulharoaparelhoem gua Ap s desembalar o apa...

Page 50: ...N o utilize para animais N O obstrua os filtros de ventila o 2 N o use o aparelho se o sensor da cor da pele 5B estiver trincado ou quebrado N o use o aparelho se o revestimento externo do aparelho e...

Page 51: ...is da pele como vitiligo ou albinismo No caso de varizes nas zonas a tratar No caso de ter sido tratada recentemente com cidos Alfa Hidr xidos AHA cidos Beta Hidr xidos BHA Retin A retinoides t picos...

Page 52: ...o aparelho sobre a pele bronzeada ou depois de exposi o recente ao sol e ou a l mpadas para bronzeamento Um uso deste tipo pode causar queimaduras graves feridas bolhas varia es na cor da pele hiper...

Page 53: ...de nascen a pintas ou verrugas antes de usar o aparelho Nunca use l quidos inflam veis como lcool produtos que contenham lcool inclusive perfumes produtos sanit rios etc ou acetona para limpar a pele...

Page 54: ...stica ser geralmente muito bem tolerada a maior parte dos utilizadores experimenta um ligeiro desconforto durante o uso geralmente descrito como uma ligeira sensa o de calor ou comich o nas zonas da p...

Page 55: ...uma queimadura ou ferida causada pelo aparelho Equimose Muito raramente o uso do aparelho pode causar equimoses azuis ou roxas que podem durar de 5 a 10 dias Enquanto a equimose clareia pode ocorre a...

Page 56: ...empo podem ser necess rias v rias sess es para a obten o uma depila o permanente A efici ncia da depila o varia conforme a pessoa e a zona de acordo com a cor dos pelos e com o n vel de toler ncia da...

Page 57: ...oras acendem de modo est vel ATEN O recomend vel iniciar sempre a primeira sess o de depila o definindo o n vel de energia mais baixo n vel 1 Se durante e depois a sess o de depila o usando o n vel de...

Page 58: ...role antes de mais nada a tonalidade da pr pria pele comparando a tabela presente na embalagem e no manual de instru es Identifique uma pequena zona a ser tratada Raspe a zona a ser tratada Ap s ter d...

Page 59: ...aluzdeliga o 11 acende oaparelho definidoautomaticamente no n vel de energia mais baixo 9 Efetuar o primeiro tratamento no n vel de energia mais baixo Se desejar modificar o n vel de energia selecion...

Page 60: ...nteparacimaparadesbloque la Inserir a l mpada de precis o 15 no man pulo pressionando o delicadamente Seguir novamente as instru es referentes ao uso do item 7 ao 18 e prestar aten o para n o sobrepor...

Page 61: ...ras de pronto para usar 6 est o a piscar para ter certeza de ter uma bom contacto com a pele e se a superf cie de tratamento 5A ou 15A est pressionada de modo uniforme e com firmeza sobre a pele OU EN...

Page 62: ...rija se ao rg o local respons vel pela elimina o ou ao revendedor do aparelho ASSIST NCIA E GARANTIA Para eventuais repara es ou aquisi o de pe as de reposi o entre em contacto com o servi o de assist...

Page 63: ......

Reviews: