IMET B034 Technical Manual Download Page 13

 

TECHNICAL MANUAL

 

Page n°13 of 25

 

RF TRANSCEIVER MODULE 2.4GHz

 

B034

 

Doc. Revision°:0

 

Date: 11/01/2021

 

 

Technical Manual file.dot 

revisione n° 0 

data: 24/02/2020

 

 

 

IMET s.r.l. 

Via Ronche, 93 33077 Sacile (PN) 

 ITALY 

 Tel. (+39) 04347878 

 Fax (+39) 0434 737848 P.IVA C.F. e Reg. Impr. PN:01106390931 R.E.A. 

43483 CCIAA PN  http//www.imet.eu e-mail

info@imet.eu

 

 

4.1 

PIN Description table  

 

PIN 

 

Symbol 

Type 

Description 

J65 

  PWDN 

LDO 

Power enable; Power ON / Power OFF the RF module 

J94 

  GND 

Ground 

Ground 

J92 

  GND 

Ground 

Ground 

J93 

  GND 

Ground 

Ground 

J80 

  GND 

Ground 

Ground 

J63 

  VREG 

Power 

Power supply input 

J12 

  GND 

Ground 

Ground 

J62 

  LED1 

GPIO 

General porpouse digital input /output use only for debug 

J100 

  LED2 

GPIO 

General porpouse digital input /output use only for debug 

J101 

  LED3 

GPIO 

General porpouse digital input /output use only for debug 

J5 

  DATA -RX 

DI 

UART Serial communication data input 

J68 

  GND 

Ground 

Ground 

J8 

  DATA-TX 

DO 

UART Serial communication data output 

J74 

  CFA-REQ 

DI 

Digital input for frequency change request 

J67 

  TM_EN 

GPIO 

Reserved for internal used 

J64 

  GND 

Ground 

Ground 

J69 

  JT 

JTAG 

JTAG signal 

J70 

  RESET 

Reset 

Microcontroller Reset PIN 

J71 

  JTCK 

JTAG 

JTAG signal 

J102 

  JTDI 

JTAG 

JTAG signal 

J72 

  JTDO 

JTAG 

JTAG signal 

J103 

  JTNRS 

JTAG 

JTAG signal 

J73 

  3.3V 

3.3V 

Power supply for microcontroller during programming phase 

DO = Digital Output ; DI = Digital Input; GPIO = general porpouse input output 

Table 3 

 

 

Summary of Contents for B034

Page 1: ...T s r l Via Ronche 93 33077 Sacile PN ITALY Tel 39 04347878 Fax 39 0434 737848 P IVA C F e Reg Impr PN 01106390931 R E A 43483 CCIAA PN http www imet eu e mail info imet eu RF TRANSCEIVER MODULE 2 4 G...

Page 2: ...LDC M880 LAC all these projects can mount the B034 module for communication It is strictly forbidden to reproduce any part of this manual in any form without the explicit written permission of the com...

Page 3: ...nal characteristics and storage 7 1 4 List of available RF channel from 2 404GHz to 2 479 GHz 8 2 0 Foto of the Device 10 2 1 Top side with Shield 10 2 1 Bottom side 10 3 0 Device Marking plate 11 4 0...

Page 4: ...ual file dot revisione n 0 data 24 02 2020 IMET s r l Via Ronche 93 33077 Sacile PN ITALY Tel 39 04347878 Fax 39 0434 737848 P IVA C F e Reg Impr PN 01106390931 R E A 43483 CCIAA PN http www imet eu e...

Page 5: ...is assembled by welding and has its own internal voltage regulators one for the RF part and one for the microcontroller logic part and its own oscillators The module can it be easily integrated surfa...

Page 6: ...verview The main technical characteristics are listed in the following table B034 MAIN CHARACTERISTICS High receiver sensitive up to 117 dBm Size 36 2 x 55 63 x 4 20 mm L x W x H with shield Wight 8 0...

Page 7: ...A PN http www imet eu e mail info imet eu 1 2 Main Application B034 is designed for industrial automation application and in particular for IMET radio REMOTE control listed in section 1 0 Device Overv...

Page 8: ...http www imet eu e mail info imet eu 1 4 List of available RF channel from 2 404GHz to 2 479 GHz In the following table is reported the list of available channels than can be used by the B034 RF modu...

Page 9: ...Ronche 93 33077 Sacile PN ITALY Tel 39 04347878 Fax 39 0434 737848 P IVA C F e Reg Impr PN 01106390931 R E A 43483 CCIAA PN http www imet eu e mail info imet eu List of Available Channels Channel Numb...

Page 10: ...Technical Manual file dot revisione n 0 data 24 02 2020 IMET s r l Via Ronche 93 33077 Sacile PN ITALY Tel 39 04347878 Fax 39 0434 737848 P IVA C F e Reg Impr PN 01106390931 R E A 43483 CCIAA PN http...

Page 11: ...king plate B034 is marking with FCC ID for Unite State as modular approval in accordance with Part 15 212 Modular Transmitter approval B034 is marking with IC ID for Canada as modular approval accordi...

Page 12: ...2021 Technical Manual file dot revisione n 0 data 24 02 2020 IMET s r l Via Ronche 93 33077 Sacile PN ITALY Tel 39 04347878 Fax 39 0434 737848 P IVA C F e Reg Impr PN 01106390931 R E A 43483 CCIAA PN...

Page 13: ...J62 LED1 GPIO General porpouse digital input output use only for debug J100 LED2 GPIO General porpouse digital input output use only for debug J101 LED3 GPIO General porpouse digital input output use...

Page 14: ...host PCB of the B034 module it is recommended to extend the ground plane at least 5mm 0 2 around the module The module was assembled using standard lead free reflow profile The module is compatible wi...

Page 15: ...2021 Technical Manual file dot revisione n 0 data 24 02 2020 IMET s r l Via Ronche 93 33077 Sacile PN ITALY Tel 39 04347878 Fax 39 0434 737848 P IVA C F e Reg Impr PN 01106390931 R E A 43483 CCIAA PN...

Page 16: ...ct to an external 2 4GHz antenna Modular certification of the B034 module is performed with the external antenna types listed in the following table TESTED EXTERNAL ANTENNA TYPES IMET CODE TYPE Nomina...

Page 17: ...iun Output Power 50 mA RX mode 40 mA Sleep mode 37 mA Receiver Characteristics Parameters Condition Min Typical Max Unit RF Input Frequency 2 404 2 479 GHz RF sensitivity 117 dBm Max RF Input 50 10 db...

Page 18: ...d Directive 2015 863 EU on the Restriction of Hazardous Substances RoHS with the following reference standard ESTI EN 301 489 1 2019 V2 2 3 ETSI EN 301 489 17 2020 V3 2 4 ETSI EN 300 328 2019 V2 2 2 E...

Page 19: ...CC approvals for intentional radiation provided no changes or modifications are made to the module circuitry Changes or modifications could void the user s authority to operate the equipment The end u...

Page 20: ...ived including interference that may cause undesired operation A user s manual for the product should include the following statement This equipment has been tested and found to complying with the lim...

Page 21: ...statement must be included as a CAUTION statement in manuals and OEM products to alert users of FCC RF exposure compliance To satisfy FCC RF Exposure requirements for mobile and base station transmiss...

Page 22: ...dentify the module within the host device The Industry Canada certification label of a module shall be clearly visible at all times when installed in the host device otherwise the host device must be...

Page 23: ...indicated Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device Cet metteur radio 26923...

Page 24: ...transmitter will also be considered approved with the transmitter and may be used and marketed with the transmitter When a measurement at the antenna connector is used to determine RF output power the...

Page 25: ...an Compliance Testing the module shall be installed in accordance with the installation instructions in this data sheet and shall not be modified When integrating a radio module into a completed produ...

Reviews: