- Lay power cables where they are not subject to risk of damage or
penetration of water into the connectors.
- Only use connectors electrically protected against water sprays.
Do not stand the machine on the power cable.
- Never use the mixer with a makeshift power connection.
-The electrical connection must be carried out by a qualified
technician.
- Ensure that the cable is securely clamped inside the plug and socket.
- Observe all accident prevention and safety standards in the work
area.
- During mixer operation, do not insert tools or other objects in the tank to
avoid damage to the mixer or operator safety hazard.
10. START-UP
Press “ON” to start the mixer.
If the mixer blades do not rotate the overload cutout switch trips to shut
down the machine. Press “ON” to resume operation.
11. OPERATION
- Ensure that the power cable is fitted with a residual current circuit
breaker upline of the machine.
- Make sure that allother persons keep clear of the mixer during operation.
- Do not use the mixer in areas subject to the risk of fire.
- Switch the mixer off before leaving it unattended.
- Make sure that the mixer is completely immobile before handling or
installation.
- Make sure that the mains voltage corresponds with the indications on
the mixer data plate.
- Make sure that the mixer blades rotate clockwise.
- Make sure that no clothing comes into contact with mixing blades.
- Warning: Never start the mixer without the safety grid fitted; the
cover is a safety device and must be fitted to avoid direct contact
with the mixer blades.
11.1APPLICATIONS
11.1.1 ADHESIVES FOR CERAMIC TILES, FLOORINGAND
WALL CLADDING
Pourinthe quantityofwateras requiredfortherelative product,considering
that the maximum mixer capacity 50 kg of adhesive.
Start the machine and during operation, pour the powder directly over the
plastic cover to obtain a smooth mixture.
Warning: when mixing large quantities, pour the product into the
tank gradually.
11.1.2 PAINT
Pour in the required amount of paint and water.
The use of acid, solvents, and other aggressive chemical products
is strictly prohibited.
11.1.3 CEMENT
Mix 60 can also mix mortar, cement, or lime provided that a fine particle
size is used.
Warning:Avoidexcessivestiffeningofthemixturedueto theaddition
of too much cement, lime or other water absorbing products.
12. EMERGENCYSTOP
- In an emergency, press the emergency pushbutton and unplug the
mixer.
- The electric motor is protected from thermal overload; if the motor
overheats the mixer is shut down automatically.Allow the motor to
cool before resuming operation.
13. CLEANING
After each work shift and before prolonged periods of disuse, clean the
tank interior and exterior thoroughly.
-Always unplugthemixerfromthemainsbeforecleaning (alsowhen
using brushes, cloths or scrapers etc.).
- Never operate the mixer during cleaning operations.
- When using water jets for cleaning, never direct the water at the mixer
drive unit.
14. MAINTENANCE
Warning: Always switch off the mixer and unplug from the power
supply before carrying out maintenance.
- Repairs to the electrical installation must be carried out exclusively by
qualified personnel.Replacement parts mustbe original IMER spare parts
and must not be modified in any way. The IMER MIX 60 is designed for
minimummaintenance requirements.However,we recommend changing
the reduction unit oil after 3000 hours continuous duty with SAE 40 oil.
Check that the socket/plug contacts are clean. If oxidised, clean
immediately.
- Used oil is considered a special waste product and must be
disposed of in accordance with the law.
- Always ensure that signs and warning notices on the machine are
clearly legible.
14. TROUBLESHOOTING
PROBLEM
CAUSE
REMEDY
The motor does not
start when switched on
No power on power
cable
Check power cables
Plug not inserted
correctly in socket
Ensure correct
connection
Faulty power cable to
electrical panel
Change power cable
Loose wire in
electrical panel
Reconnect wire
Loose wire in motor
terminal board
Reconnect wire
Faulty main switch
Replace switch
Residual current
circuit breaker tripped
Reset switch. If it does
not reset, refer to a
qualified electrician to
check the electrical
system to ensure
complete safety.
The motor does not
stop when the safety
grid is lifted
Faulty limit switch
Replace limit switch
Motor starts with
difficulty
Mixture is too stiff
Reduce mixture
quantity or dilute and
try again.