background image

 
 

12 

 

 

5.3. 

Connectivity 

 
The Access Station Micro needs Internet access to operate. 
It can be connected via Ethernet cable (RJ45 port on PoE injector) or Cellular USB 
dongle (USB port on station). 
When both connections are used to improve link robustness, the Ethernet one is 
automatically set as primary and Cellular is set as secondary backup. 

 
 

 
 

5.3.1. 

Ethernet connectivity 

 

Ethernet connection of the PoE injector can be provided by DSL modem, satellite 
modem, any kind of backhaul connection or private LAN. 
In  case  of  private  LAN  or  direct  Backhaul  connection,  the  host  network  should 
receive proper configuration to allow the IP communication between Sigfox Access 
station and Sigfox Cloud. 

 

Performance requirement: 
Minimum Throughput: 512 Kbit/s (DL) and 128 Kbit/s (UL) 
Maximum latency: 2 s 

 

The following table lists communication ports (inbound and outbound) that must be 
open on the host network firewall: 

 

Port

 

Connection 

protocol

 

Purpose

 

Destination IP

 

53 

UDP 

DNS 

IP provided by DHCP 

lease 

443 

TCP 

Communication with Sigfox Cloud 

185.110.96.0/22 

1194 

UDP 

Separate VPN 

185.110.96.0/22 

500 

UDP 

Separate VPN 

185.110.96.0/22 

4500 

UDP 

Separate VPN 

185.110.96.0/22 

 
 For more details, please contact your Sigfox Operator. 

www.ime.de

19-10-20

Summary of Contents for SBMS-T4

Page 1: ...system documentation is official and applicable This document is confidential and is the property of Sigfox It shall not be copied and or disclosed to third parties in any form without Sigfox written...

Page 2: ...e length 10 5 2 3 Power consumption 11 5 3 Connectivity 12 5 3 1 Ethernet connectivity 12 5 3 2 Cellular connectivity 13 5 4 Commissioning 13 5 5 LED status 14 6 Annexes 15 6 1 Labels 15 6 1 1 Product...

Page 3: ...x Access Station Micro series are ultra wide range high linearity transceivers units and feature first class performance radio and innovative software defined radio processing for use in Ultra Narrow...

Page 4: ...Accessories available separately Sealing cover USB cellular dongle containing a specific firmware compatible with Sigfox Access Station Cellular Type Model Firmware Zone 3G MS2131i 8 SIG 21 751 11 00...

Page 5: ...with third party SRD ISM systems operating on the same band is forbidden Regardless the type of installation the base station must be installed away from obstacles possibly altering the reception and...

Page 6: ...side 4 2 Access Station Mounting The following table describes the different mounting options offered with the kit included in the package Wall Mounting Pole Mounting Kit 2 screws 4 5x30mm anchors for...

Page 7: ...4 Site selection Radio performance will depend on site configuration Whatever the type of installation the station should be clear of massive obstacles or metallic surface within 1m since possibly al...

Page 8: ...the last floor in case of cellular BS on the roof and away from windows to reduce RF interferers from cellular broadcasters Note When installed vertically on a wall the connector must be facing downw...

Page 9: ...9 4 4 2 Outdoor For outdoor deployment it is recommended to place the Access Station Micro above facing and in the periphery of the connected devices for best result www ime de 19 10 20...

Page 10: ...age range 11V DC to 26V DC from the supplied PoE injector Station minimum input voltage 10V DC Max input current 1A Injector DC connector 5 5mm x 2 1mm Note The station cannot be powered with IEEE 802...

Page 11: ...atures Typical 2 3W RX mode or 4W TX mode with Ethernet connection Average power consumption with warm up mode 4 8W Peak consumption 7 5W with heating mode Heating mode 6 3W temperature 0 C Use of cel...

Page 12: ...ivate LAN or direct Backhaul connection the host network should receive proper configuration to allow the IP communication between Sigfox Access station and Sigfox Cloud Performance requirement Minimu...

Page 13: ...g Commissioning of the station is done online by the Sigfox Operator via the Backend interface Pre commissioning modification of network settings and registering site location can be done with the Acc...

Page 14: ...upport Orange Flashing Establishing connectivity IP not allocated If the light remains flashing orange after 1 minute check network connection Check DHCP server and IT configuration Orange Establishin...

Page 15: ...as been validated for a country the product will be compliant and the label will be updated if necessary Check the lasted version of the Safety notice Product certifications available online for up to...

Page 16: ...latory groups for SMBS T4 REGULATORY GROUP RADIO ACCESS MODE OPERATING BAND MAX OUTPUT RADIATED POWER EIRP COUNTRY A FH 915 928MHz 23dBm AUSTRALIA B FH 902 907 5 915 928MHz 23dBm BRAZIL C FH 915 928MH...

Page 17: ...NVIRONMENTAL Product weight 450g 1 lb Operating temperatures 20 C to 55 C Storage temperatures 30 C to 85 C Robustness MTBF 92 000 hours Casing material Plastic ASA PC Dimensions in mm Sealing cover w...

Reviews: