Terminalis 12 and 13
Auxliary suppy:
direct or alternating current electrical supply which is necessary for proper working of the device.
Please verify that the available supply voltage meets the one shown on the data label of the meter (voltage value and any frequency).
Where a double voltage is shown (for instance 20…60V ac / 20…150 V dc)
the meter can be fed with alternating voltage 20…60V ac
or direct voltage 20…150V dc.
In case of direct voltage supply please respect
the shown polarities
12+
and
13
11/14 1073180 E
cod.DG3P0.P5 - DG8P0.P5 - DG9P0.P5
15
Digital meters
Programming
Direct Current 5.0
Direct Current 5.1
Ex.
input 10A
Input -10...+10A
Display -10.00A...+10.00A
Ex.
input 1.5A
Input -1.5...+1.5A
Display -1.500...+1.500A
Simultaneously press the keys
Increases the value
Cursor position
3 sec.
Press and keep the keys pressed for at least
3 seconds
.
When the keys are relased, the meter enters
the programming value
(Inp)
LEGEND