Page | 7
INSTALLATION
For the Installer
These Instructions contain important information designed to help the user
obtain the maximum benefit from their investment in a Lincat/IMC Ventus Bottle
Cooler.
Please read them carefully before starting work, and consult with the supplier in
the event of any queries.
Be sure to leave this Instruction Manual with the user after installation of the
machine is complete.
Procedure
WARNING
The following table shows the weight and the minimum quantity of
people required to lift each unit:
Bottle Cooler
Net Weight
Quantity of
People
V60 (all variants)
57.5 kg (max)
2
V90 (all variants)
76.5 kg (max)
4
V135 (all variants)
125 kg (max)
4
Install the unit on a flat and level floor. Ensure a minimum 10mm
clearance either side of the unit, there is to be a minimum 20mm clearance
at the top and a minimum 60mm clearance at the back.
The V135 is supplied on castors to aid installation and cleaning. Do not install
the unit close to a heat source such as a radiator or a warm air outlet. Ensure
that the unit is standing level by adjusting the feet on the base of the unit.
The unit has an automatic defrost cycle and evaporates all the condensate
water without the need for a drainage system.
NOTE!
The castors on the V135 are to aid installation only. The machine is not
designed to be used as a mobile unit.
It is important to install the Bottle Cooler on a flat surface. This ensures
that the doors are level. Adjustment is provided via the feet, to enable the
installer to level the cabinet. Engineer Call-outs in order to level Bottle
Coolers, will not be covered under warranty.