background image

MR60 – GLASS FROSTER

 

 

 

 
CHANGING AN LED LIGHT FITTING 

 
The cabinet interior is illuminated by a LED light strip fitting located at the front 
of the top inner panel.  
 
To change the light assembly: 

·

  Ensure the mains power to the unit has been turned off. 

·

  Open the front cabinet door(s). 

·

  Unscrew the screws holding the LED assembly in place. 

·

  Carefully lower the LED assembly down and disconnect the 2 wires from the 

unit. 

·

  The LED light assembly should now be free to fully remove from the unit. 

·

  To fit the replacement unit. 

·

  Place the new LED light assembly inside the unit, re connect the 2 wires 

from the unit to the new LED light assembly. 

·

  Re fit the LED light assembly inside the unit by using the screws. 

·

  Re-connect the mains power and ensure the light illuminates by means of 

the switch. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fixing  
Screw

LED Light 
Assembly 
crews 

LED Light 
Assembly 
ews 

Summary of Contents for MR60

Page 1: ...lass Froster Series 1 Imperial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 729990 Service Fax 44 0 1978 667766 Spares Fax 44 0 1978 667759 E mail info imco co uk Website www imco co uk A34 100 R1 ECN 8848 May 2019 ...

Page 2: ...tion requirements of the Electromagnetic Compatibility Directive 2014 30 EU and manufactured in accordance with harmonised standards EN 61000 6 1 2001 Immunity and EN 61000 6 3 2007 Emissions plus product specific standards They also satisfy the essential health and safety requirements of the Low Voltage Directive 2014 95 EC and are manufactured in accordance with standards BS EN 60335 1 and BS EN...

Page 3: ...T FITTING 9 ELECTRICITY SUPPLY CONNECTION 10 COMMISSIONING 10 CHANGING THE CONTROLLER SET POINT 11 USING YOUR GLASS FROSTER 11 CLEANING 12 CHANGING SHELF POSITION 12 MAINTENANCE 13 DO S AND DON TS 14 ORDERING SPARE PARTS 15 END OF LIFE DISPOSAL 15 MATERIAL CONTENT 15 WIRING DIAGRAM 16 SPARES LIST DRAWING 1 17 SPARES LIST DRAWING 2 18 SPARES LIST 19 NOTES 20 ...

Page 4: ...t covered by the guarantee The guarantee applies in this form to installations within the United Kingdom Export units carry 2 years parts only warranty Please observe these instructions carefully DELIVERY The packaged machine consists of MR60 Glass Froster containing Shelf Full size Shelf base size Shelf clips Sets of keys 2 1 8 2 Instruction Booklet 1 Please notify both the carrier and the suppli...

Page 5: ...ge is a back bar or under bar glass froster designed for the frosting and storage of glasses The following quantity of standard pint glasses can be held in each unit Glass Froster Capacity Standard Pint Size Glass MR60 900h x 600w x 500d MR60 800h x 600w x 500d 50 50 ...

Page 6: ...MR60 GLASS FROSTER 6 MR60 Dimensions MODEL X Y MR60 900mm 500 900 MR60 800mm 500 800 X mm Y mm 600mm MR60 ...

Page 7: ... MR60 all variants 57 5 kg max 2 Install the unit on a flat and level floor Ensure a minimum 10mm clearance to either side of the unit there is to be a 20mm clearance at the top and 60mm clearance at the back Do not install the unit close to a heat source such as a radiator or a warm air outlet Ensure that the unit is standing level by adjusting the feet on the base of the unit The unit has an aut...

Page 8: ...cabinet is illuminated by a LED light unit this light can be turned on or off by depressing the switch that is located on the underside of the worktop To access this switch the door must be opened When the switch is flush the lights are on Light Switch ...

Page 9: ...y in place Carefully lower the LED assembly down and disconnect the 2 wires from the unit The LED light assembly should now be free to fully remove from the unit To fit the replacement unit Place the new LED light assembly inside the unit re connect the 2 wires from the unit to the new LED light assembly Re fit the LED light assembly inside the unit by using the screws Re connect the mains power a...

Page 10: ... NOT be used until a replacement fuse cover has been obtained and fitted or the plug replaced WARNING This machine must be earthed Should the supply cord become damaged then a replacement must be fitted by an approved electrician The IEE Codes of Practice must be observed The wires in the mains lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live C...

Page 11: ...ked after closing at night or first thing in the morning to allow time for the glasses to cool Ensure that stock is rotated by placing new stock at the back of shelves or in one side of the cabinet to ensure that colder glasses are used first Do not leave the doors open when the unit is running as this causes the evaporator to ice up preventing the unit from operating efficiently Ensure that the f...

Page 12: ... The unit can be washed on the inside using bicarbonate of soda to remove stale smells CHANGING SHELF POSITION The shelves in all MR60 Glass Froster units are fully adjustable To adjust the shelves Remove the shelf Unclip the shelf supports as shown below Hook the shelf supports in the required location Ensure all shelf supports are at the same height for a level shelf The support strips are numbe...

Page 13: ...d insulation block inside the cabinet after switching the unit off from the mains supply Clean the compressor coil with a brush and vacuum cleaner THIS MUST BE DONE every three months or when dirty whichever is sooner Re fit the insulation and service panel and secure with the original screws Once the service panel has been re fitted clean the grille at the bottom front of the cabinet Re connect t...

Page 14: ...ace Do Ensure plug is accessible with the unit installed Do Regularly clean the condenser and compressor Do Rotate stock of glasses Don t Sit or stand on the unit worktop Don t Load with boxed goods Don t Leave the doors open Don t Cover the shelves with any protective materials which may obstruct air circulation through them Don t Install unit in direct sunlight Don t Block the air inlet grilles ...

Page 15: ...pleting substances The unit must be sent to a specialist recovery recycling and disposal site that is licensed for the disposal of refrigerated equipment Please note that the insulation in the MR60 range does not contain any ozone depleting substances The refrigerant used in the MR60 is R404a IMC can arrange removal of your redundant Glass Frosters transfer to safe storage and disposal For more in...

Page 16: ...MR60 GLASS FROSTER 16 WIRING DIAGRAM ...

Page 17: ...MR60 GLASS FROSTER 17 SPARES LIST DRAWING 1 Door Gasket Evaporator Fan Pilaster Strip Door Controller Shelf Glider Foot Lock Shelf Clip ...

Page 18: ...MR60 GLASS FROSTER 18 SPARES LIST DRAWING 2 Plastic Drip Tray Compressor Fridge Pack Mains Cable ...

Page 19: ...ider Foot A21 011 Lock clip keys E76 221 Access panel G30 562 Electronic Controller G42 020 Plastic Drip Tray G60 348 M1 Mains Cable S49 066 S49 071 Refrigeration Pack 900 Refrigeration Pack 800 J09 049 Condenser fan motor assembly J09 026 Evaporator J09 007 Service Drier X08 057 2mtr Capillary V60 G96 049 Evaporator Fan C46 001 Z Door Handle State Colour S76 250 S76 253 S76 256 S76 259 LED Assemb...

Page 20: ...MR60 GLASS FROSTER 20 NOTES ...

Page 21: ...MR60 GLASS FROSTER 21 ...

Reviews: