3.2 HMI Touch Screen
Press to English to next page, and press Auto to switch to the Manual mode
On the Manual mode screen
Motor start:
This is to control the Tube holder running
Feeding cylinder start: This is to control the Tube holder feeding
Ultrasonic cylinder start: This is to control the up mould and down mould working.
Trimming cylinder start: This is to control the cutter
Ultrasonic start:
This is to control the frequency, this is same as the “18. OSC
check”
Tube Orientation on : This is to control the Sense off/on
Time setting:
This is to Adjust the Delay time/ Welding time/Holding
time
Delay time:
0.80
Welding time:
Tube Diameter 20, the time will about: 0.20,
Tube Diameter 30, the time will about 0.40
Tube Diameter 40, the time will about 0.50
Tube Diameter 50, the time will about 0.7
Holding time:
0.35