Summary of Contents for IMCHX-007 Series

Page 1: ...1 IMCHX 007 Series of Ultrasonic Soft Tube Sealing Machinery INTERNATIONAL MACHINE CONCEPTS WELCOMES YOU TO YOUR NEW MACHINE Operation Manual Date 2016...

Page 2: ...c connections 1 4 Chapter 2 Technical Parameters and Description 2 1 Chapter 3 Operation Instruction Machine layout 3 1 HMI Touch Screen 3 2 Operation process 3 3 Chapter 4 Malfunctions Faults and the...

Page 3: ...sembled These need to be fitted to the machine to resemble the photos above the machine The machine is fixed to the wooden pallet by four metal brackets Remove these brackets and discard or keep for f...

Page 4: ...e machine check if the machine is level by Level Instrument If not please adjust the four legs Check every part of the machine carefully for damage during shipping Tighten any loose parts screws and m...

Page 5: ...2 1 Technical Parameters and Description Rated Voltage AC220V 50 60HZ singe phase Sealing Diameter 5 50mm Max tube height 5 250mm Machine Power 1 5KW Production Speed 8 16 tubes min Outline Dimension...

Page 6: ...ld 14 Power lamp 5 Back mould 15 Power switch 6 Cutter 16 Operational plate 7 Gas pressure meter 17 Tune 8 Gas pressure adjustment 18 OSC check 9 Emergency button 19 Over load lamp 10 Start button 20...

Page 7: ...and down mould working Trimming cylinder start This is to control the cutter Ultrasonic start This is to control the frequency this is same as the 18 OSC check Tube Orientation on This is to control...

Page 8: ...d will close Set Moulds gap adjustment let the two moulds just touch with no gap Press Cutter controller and confirm the cutter works smoothly You need to put the plastic tube in the tube holder when...

Page 9: ...air Connect power and compressed air Low compressed air pressure Increase air pressure Plastic overflow or not good after welding Two moulds too closed or too parted Adjust the gap between two moulds...

Page 10: ...10 Chapter 5 Electrical diagram...

Page 11: ...11 Chapter 6 6 1 list of Spare parts Num Spare parts name Picture 1 Power board 2 Electric eyes 3 Cutter 4 Transducer 5 Electromagnetic valve...

Page 12: ...12 6 Upper mould 7 Lower mould 8 Main board 9 PLC 10 Tube holder...