3
the equipment.
3. The equipment must be used in a dry, clean and ventilated environment,
away from various types of heat sources.
Operating in the wet environment with severe acid corrosion will significantly
shorten the use life of equipment.
For use in places with many dusts, the dusts in the sensor head and the host
must be cleaned regularly.
4. The machine is only applicable for the sealing operations on plastic, glass,
paper and other containers,
but NOT suitable for
those on metal and other
derivative capacitors.
5. The requirements of induction machine sealing for selection of the sensing
membrane and the bottle cap:
(1) The material of used sensing membrane must be the same as that of the
sealed bottle.
(2) The optimum thickness range of foil on the sensing membrane is between
0.012 and 0.03mm. For the sensing membrane with the aluminum foil being
less than 0.012mm in thickness, sealing speed and quality are not
guaranteed.
(3) The vacuum aluminum plating composite membrane similar to aluminum foil
induction membrane must not used.
(4) When using the sensing membrane without paper pad, the bottle mouth and
cap must be smooth and without deformation.
(5) It is not applicable to non-threaded object sealing using the cover, as the
cover can not completely press the sensing membrane flatly and tightly,
resulting in the phenomenon of loose sealing closure.