background image

 

FROSTAR FR60 AND FR90 

 
INSTALLATION, OPERATING AND MAINTENANCE MANUAL 

PLEASE LEAVE WITH OPERATOR 

 

 

 
 
 

FROSTAR FR60 AND FR90 SERIES 5 

 
Imperial Machine Company Limited 
Unit 1, Abbey Road 
Wrexham Industrial Estate 
Wrexham LL13 9RF 
Tel: +44 (0)1978 661155 
Fax: +44 (0)1978 729990 
Service Fax: +44 (0)1978 667766 
Spares Fax: +44 (0)1978 667759 
E-mail: 

[email protected]

 

Website: www.imco.co.uk 
 

A34/019 R4                                                                  ECN 8704 JANUARY 2018 

Summary of Contents for Frostar FR60

Page 1: ...TAR FR60 AND FR90 SERIES 5 Imperial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 729990 Service Fax 44 0 1978 667766 Spares F...

Page 2: ...equirements of the Electromagnetic Compatibility Directive 2004 108 EC These products are manufactured in accordance with harmonised standards EN 61000 6 1 2001 Immunity and EN 61000 6 3 2001 Emission...

Page 3: ...UARANTEE 1 DELIVERY 1 INTRODUCTION 2 INSTALLATION 4 PREPARATION 4 CHANGING THE CONTROLLER SET POINT 5 OPERATION 6 MAKING THE BEST USE OF THE CABINETS 6 MAINTENANCE 7 ORDERING SPARE PARTS 7 FR60 FR90 W...

Page 4: ......

Page 5: ...ee Please observe these instructions carefully The guarantee applies in this form to installations within the United Kingdom DELIVERY The packaged machine consists of Frostar Unit 1 Instruction Bookle...

Page 6: ...ing top loaders with sliding covers suitable for underbar use The Frostar range is designed to produce a steady supply of chilled glasses Frostar FR60 Dimensions Internal Dimensions The internal dimen...

Page 7: ...FROSTAR FR60 and FR90 3 Frostar FR90 Dimensions Internal Dimensions The internal dimensions of the FR90 are 550mm high by 826mm wide by 500mm deep REFRIGERATION CONTROLLER...

Page 8: ...um of two hours before starting This will avoid damage to the compressor PREPARATION The electrical supply to the unit should be 220 240 Volt 1 phase 50 Hz All units are supplied with a standard mains...

Page 9: ...ow the factory setting min 30 C max 5 C by following the button sequence below Press the SET button once SET will appear 1 SET Using the up and down buttons scroll to the desired set point temperature...

Page 10: ...o be used for several weeks run it for 24 hours after emptying it to ensure that all condensate water evaporates MAKING THE BEST USE OF THE CABINETS Do not overload the cabinet There should be a gap o...

Page 11: ...than regular cleaning the Frostar range requires no maintenance by the end user It is recommended that an IMC approved engineer services the unit at least once a year For further advice or assistance...

Page 12: ...8 FROSTAR FR60 and FR90 FR60 FR90 WIRING DIAGRAM G99 049 007 T1 CABINET AIR TEMP T2 EVAPORATOR COIL TEMP...

Page 13: ...inted G30 420 Defrost Controller G30 420 Defrost Controller G42 011 Compressor G42 010 Compressor G45 062 On Off Switch G45 062 On Off Switch G50 132 Fluorescent Light G50 133 Fluorescent Light G95 00...

Reviews: