Machine does not start
Cause
Action
Electrical supply is not turned on.
Switch on supply.
The mains isolator has tripped.
Call site electrician to reset the isolator. If
problem persists contact service personnel.
Waste bin is full (flashing red light)
Empty and then replace the bin
Waste bin is out of position (solid red light)
Replace the bin in its correct position inside the
bin enclosure on the machine.
Baffle is not correctly fitted.
Check baffle is in position and secured. If
problem persists contact service personnel.
One of the motor overload relays has tripped.
Rectify the problem then reset the overload
relay.
Emergency stop button has been pressed.
Deal with the emergency then reset the button
by turning it clockwise as shown on the button.
Unexpected system stop
Cause
Action
Electrical supply turned off.
Switch on supply.
The mains isolator has tripped.
Call site electrician to reset the isolator. If
problem persists contact service personnel.
Waste bin is full (flashing red light)
Empty and then replace the bin
Waste bin is out of position (solid red light)
Replace the bin in its correct position inside the
bin enclosure on the machine.
Baffle is not correctly fitted.
Check baffle is in position and secured. If
problem persists contact service personnel.
Motor overload has tripped.
Allow motor to cool for 10 minutes and restart.
If problem persists contact service personnel.
Emergency stop button has been pressed.
Deal with the emergency then reset the button
by turning it clockwise as shown on the button.
Waste jammed in disposer grinding unit.
Remove blockage from grinding unit.
See instructions on page 3.
Waste not processed
Cause
Action
A blockage has occurred in the waste pipe.
Clear blockage from waste pipe.
Slurry in Bin
Cause
Action
Feeding too quickly.
Allow to clear and feed more slowly.