IMC EAGLE 2 SOLR-2ELC-10 Service And Parts Manual Supplement Download Page 2

INSTRUMENTATION WITH QUALITY ENGINEERING

INSTRUMENTS, INC. 

INSTRUMENTATION WITH QUALITY ENGINEERING

INSTRUMENTATION WITH QUALITY ENGINEERING

INSTRUMENTS, INC. 

INSTRUMENTS, INC. 

®

COL=174.1            STO= 1 10 . 4

PKH =18 0.4           PKL= 6 0 . 1

AX1=-10.5                AX2= 17 5 . 3

PMP= O N                          UPL=ON      

COL=174.1            STO= 1 10 . 4

PKH =18 0.4           PKL= 6 0 . 1

AX1=-10.5                AX2= 17 5 . 3

PMP= O N                          UPL=ON      

COL=174.1            STO= 1 10 . 4

PKH =18 0.4           PKL= 6 0 . 1

DI F=0 8 . 0                H IL= 17 5 . 3

PMP= O N                          UPL=ON      

    

    

COL=174.1            STO= 1 10 . 4

PKH =18 0.4           PKL= 6 0 . 1

DI F=0 8 . 0                H IL= 17 5 . 3

PMP= O N                          UPL=ON      

    

    

PAGE 2

PAGE 1

An 

IMC LCD MASTER DIGITAL DISPLAY PANEL

 can also be connected to the DATA PORT.  It has an RJ-45 

jack and is supplied with a 3 foot long cable that can be substituted with a standard CAT5 cable up to150 feet long.  
These ethernet cables are available at most retail stores.  The display panel also has a PEAK RESET button 
located on the side to reset previous STORAGE temperature peaks.

The Information on the 

LCD MASTER DISPLAY PANEL

 is displayed as follows:

COLLECTOR  TEMPERATURE  
STORAGE  TEMPERATURE
DIFFERENTIAL  CONTROL  SETTING
HI  LIMIT  CONTROL  SETTING
PUMP  STATUS
UPPER  LIMIT  STATUS 
PEAK  HI=  MAXIMUM  TEMPERATURE
PEAK  LO=  MINIMUM  TEMPERATURE
AUXILIARY  SENSORS  1  AND  2

This  Master  LCD  has  a  second  page  that  will 
display  the  auxiliary  sensor  temperatures.  
To  display,  press  and  release  the  PAGE/RESET 
button  on  the  side  of  the  display  housing.  
The  auxiliary  sensors  will  be  displayed  within  2 
seconds.   To  RESET  the  STORED  PEAK 
temperatures  of  the  storage  tank,  press  and  hold 
for  6  seconds  the   PAGE/RESET  button.   The 
current  temperatures  will  appear  after  the  button 
is  released.  The  Master  LCD  display  is  updated 
every  2  seconds. 

DATA-PORT

Requires an IMC Data-Port ADAPTER that will allow interface to a standard computer’s serial RS232 port. The 
ADAPTER can also accept a serial to USB converter to connect directly to portable computers that only have 
USB  ports.    If  wireless  operation  is  desired  for  short  distances,  BLUE  TOOTH  transceiver  can  also  be 
connected. The rate at which the data is sent from the EAGLE solar controller is determined by a jumper in the 
controller as show in the CONTROLLER diagram on page 4.  If the jumper is placed on position labeled “2S”, 
one complete line of “total system information” will be sent to the computer every 2 seconds which is necessary 
when performing diagnostics or a system startup. If the same jumper is placed on position labeled ”6M”, then 
data will be sent every 6 minutes. This will allow a more suitable data-send rate for long-term DATA LOGGING, 
specially when storing the data in a “CAPTURE” file setup in the computer’s communications program such as 
“Terminal” or “Hyper Terminal”.

SAMPLE DATA PORT PRINT

RUNTIME COLL-T  STOR-T  DIFF-T  HILI-T  AUX-1  AUX-2   PUMP UPLim FAULT
0:00    125.9   73.7    08.0    110.0   212.2   205.4   ON  OFF                    

S

ystem collecting solar HEAT

0:06    25.9    73.7    08.0    110.0   212.2   205.4   OFF OFF   LO-TMP->OFF      

System in LO TEMP shut down PUMP->OFF

0:12    25.9    73.7    08.0    110.0   212.8   205.4   ON  OFF   PmpSW!

        

Pump switch ON

0:18    OPEN.S  73.9    08.0    110.0   212.8   205.4   OFF OFF   SENS!, PmpSW!    

O

pen sensor, pump switch OFF

0:24    -16.0   74.7    08.0    110.0   25.9    184.6   ON  OFF   FREZE-PMP->ON    

System in Freeze protect mode PUMP->ON

0:30    SHRT.S  74.9    08.0    110.0   25.9    154.6   OFF OFF                    

Shorted sensor->System OFF

0:36    125.9   173.7   08.0    173.0   112.2   95.4    OFF ON                     

Storage reached UPPER LIMIT

Summary of Contents for EAGLE 2 SOLR-2ELC-10

Page 1: ...ctable overrides for low temperature shut down or freeze protection modes for safe operation MAIN FEATURES Microprocessor accuracy and dependability with ambient operation from 10 to 120 F Large easy...

Page 2: ...Master LCD display is updated every 2 seconds DATA PORT Requires an IMC Data Port ADAPTER that will allow interface to a standard computer s serial RS232 port The ADAPTER can also accept a serial to U...

Page 3: ...er must be placed onto the jumper pins marked LO on the circuit board Only ONE of these two override features can be enabled FREEZE PROTECTION OVERRIDE This feature is available to prevent a non drain...

Page 4: ...ure the strands are tightly twisted Using a elect the appropriate screw and turn CCW to open the terminal hole fully Then guide the wire into the terminal hole and hold while tightening turn CW the sc...

Page 5: ...HP NC 20 A RES 1 2 HP TEMPERATURE SENSORS 4 SHD CABLE SHIELDS COL COLLECTOR STO STORAGE AX1 2 OPTIONAL USE 1 8 WIDE BLADE SCREW DRIVER TURN CCW TO OPEN HOLE FOR WIRE 22 TO 18 GA OVERRIDE JUMPERS ONE O...

Page 6: ...n RJ 45 plug EAGLE web controller with a 2500 volt isolated PORT is recommended for long term or permanent installations Immersion style 4 long with 1 4NPT fitting SOLR TS04 1 2NPT fitting SOLR TS24 8...

Page 7: ...devices specifically designed by IMC Instruments to be connected to these ports ACCESSORIES continued LCD MASTER DIGITAL DISPLAY PANEL SOLR RD80 Displays temperature and status indication with 80 cha...

Page 8: ...VER 11 01 08 PRINTED IN U S A...