IMC Networks IE-iMcV-MuxDemux/4 Operation Manual Download Page 5

2

 

Installing an iMcV-Module 

The IE-iMcV-MuxDemux/4 installs in IMC Networks’ iMediaChassis series or in any 
MediaChassis/2.  It occupies 2 slots as it is dual wide. 

The IE-iMcV-MuxDemux/4 can be installed in a 2 slot unmanaged chassis: 

 

IE-MediaChassis/2-AC 

 

IE-MediaChassis2-DC 

 

MediaChassis/2-AC 

 

MediaChassis/2-DC 

 

MuxDemuxChassis/2 

 

 

NOTE 

All modules are hot-swappable. 

 
To install an IE-iMcV-MuxDemux/4 
1.

 

Remove the blank bracket covering the slot where the module is to be installed 
by removing the screws on the outside edges of the bracket.   

2.

 

Slide the IE-iMcV-MuxDemux/4 into the chassis, via the cardguides, until the 
module is seated securely in the connector.   

3.

 

Secure the module to the chassis by tightening the captive screw.   

4.

 

Save any “blanks” removed during installation for future use if the configuration 
requirements change. 

5.

 

The MuxDemuxChassis/2 is a 2 slot chassis without a power supply, as the IE-
iMcV-MuxDemux/4 does not require power to function. 

Summary of Contents for IE-iMcV-MuxDemux/4

Page 1: ...IE iMcV MuxDemux 4 CWDM System Operation Manual...

Page 2: ...End user agrees to accept all liability for loss of or damages to the returned product during shipment IMC Networks shall repair or replace the returned product at its option and return the repaired...

Page 3: ...the IE iMcV MuxDemux 4 CWDM System 1 Installing an iMcV Module 2 Connecting the IE iMcV MuxDemux 4 3 Specifications 4 IMC Networks Technical Support 5 Fiber Optic Cleaning Guidelines 6 Electrostatic D...

Page 4: ...ansion Port to Daisy Chain Multiple Mux 6 Network Port Network Port The IE iMcV MuxDemux 4 is a dual wide module that provides 4 channels of CWDM Coarse Wavelength Division Multiplexing an expansion p...

Page 5: ...IE iMcV MuxDemux 4 1 Remove the blank bracket covering the slot where the module is to be installed by removing the screws on the outside edges of the bracket 2 Slide the IE iMcV MuxDemux 4 into the c...

Page 6: ...he wavelengths enabling the fiber optic receivers to receive a signal of the correct wavelength Port 5 Port 5 is an expansion port to allow multiple IE iMcV MuxDemux 4 to be daisy chained or to carry...

Page 7: ...ical band between 1450nm and 1610nm NOTE Unit does not require power to operate Operating Temperature 40 F to 185 F 40 C to 85 C Storage Temperature 40 F to 185 F 40 C to 85 C Humidity 5 to 95 non con...

Page 8: ...5 IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com...

Page 9: ...se problems in an installation 2 Dust caps are installed at IMC Networks to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber ca...

Page 10: ...available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 Aft...

Page 11: ...d waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps t...

Page 12: ...information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document IE iMcV MuxDemux 4 is a trademark of IMC Networ...

Reviews: