background image

3.  Initialize a single RFID tag— 

  Click on the 

RFID Tag Intialization 

tab on the Imation RFID Cartridge 

Tracker Software (Section 3.4 of the DataGuard rf Tape Tracking System 
manual). 

 Initialize the RFID tag on a single cartridge by clicking on 

Init RFID Tag 

If the antenna senses more than one 

RFID tag, it will send an error 

message to the Scan Station.  The antenna 

only initializes one tag at a

a time in order to avoid writing incorrect data to 

any tag.

Monitoring the Scan Station Operation: 

 

6

The Scan Station reader uses a series of lights (LEDs) to display its activity during the 
scanning or initialization process.  Position the Scan Station so the operator can observe 
the LEDs while scanning or initialization (Figure 6). 
   

 

 
 

Figure 6

 LED 

1—Green 

o

  The green flashing LED indicates that the reader is working properly. 

  LED 2—Blue  

o

  Short flashes indicate error-free communication with the antenna pad 

during scanning or initialization. 

o

  This LED will flash alternately with green LED 1 if the Scan Station is 

reset after a software update or if there is a data error after its internal 
check after a software update. 

 LED 

3—Yellow 

o

  Short flashes indicate communication with the host computer over the 

RS-232 cable. 

  LED 4—Yellow (reserved for future use)  

  LED 5—Red  

o

  This LED lights up if there is an error with the antenna pad.  For 

example, it will flash if the antenna pad is placed too close to a large 
piece of metal. 

o

  This LED also briefly flashes when the Scan Station reader is turned 

on or reset. 

 

 

Warranty? 

 
 

Product Specifications 

 

 

 

 

  

  

 

Scan Station                             Antenna Pad       

 

 

               

                

Model DGSCN-100                Model DGANT-100 

Physical Data: 
 

Dimensions                    

 

 

41.9 x 19.1 x 12.7 cm

         

 64.75 x 49.5 x 11.4 cm 

      (16.5 

7.5 

inches) 

 

 

      (25.5 x 19.5 x 4.5 inches)

  

 

 

Weight                                 

 

3.47 kg    (7.65 lbs.)             9.53 kg    (21 lbs.)

          

 

Summary of Contents for DataGuard rf Scan Station

Page 1: ...rf RFID Antenna Pad Model DGANT 100 Safety Instructions please read thoroughly before using the Scan Station Always follow the basic precautions listed below to avoid the possibility of serious injury...

Page 2: ...s device and easily accessible Use this device only with the Imation DataGuard rf Tape Tracking System and associated software Pacemaker warning The Scan Station creates an electromagnetic field below...

Page 3: ...t the operator can observe the activity LEDs see below during scanning or initialization of the tags o The antenna pad must be at least 50cm 20 inches away from large pieces of metal Large pieces of m...

Page 4: ...e for cartridges and for cases Placement of Cases and Cartridges Case place the non metallic case centered in the grooved outline on the top of the antenna pad Figure 3 o The RFID labels on the cartri...

Page 5: ...ape Tracking System manual for a full description of that software The antenna pad is used to scan the RFID tags on non metallic storage cases or individual cartridges or to initialize an RFID tag on...

Page 6: ...icates that the reader is working properly LED 2 Blue o Short flashes indicate error free communication with the antenna pad during scanning or initialization o This LED will flash alternately with gr...

Page 7: ...d 2 this device must accept any interference received including interference that may cause undesired operation Modifying this device may void the user s authority to operate the device CANADA This de...

Page 8: ...8 Europe Restrictions for operating the DGSCN 100 as of October 2006 ERC REC 70 03 Annex 9 Band F1 Operation not currently permitted BEL GRC LUX NOR LVA HRV ROU IRL LIE SUI BUL LTU...

Reviews: