3
Technical Data
Page 8 / 39
IMAGO Technologies GmbH
Strassheimer Str. 45; 61169 Friedberg; Germany; Tel. +49(0)6031-6842611
3
Technical Data
Operating Conditions
Power Supply:
Parameter
Min
Typ.
Max
Unit
Supply voltage
11
26.4
V
Supply voltage for use with internal ring light
24
V
Supply current
1
(@24V)
0.25
A
RS-232:
Parameter
Min
Typ.
Max
Unit
RX signal input range
–
25
25
V
TX output voltage swing (R
L
=
3 kΩ
)
5
5.4
V
Data rate, R
L
= 3kOhm, C
L
= 1000 pF
1200
115200
bps
Digital Input:
Parameter
Min.
Typ.
Max.
Unit
Input voltage range
0
30
V
Input current range (limited by internal circuit)
0
21
mA
Threshold voltage
6
11
V
Threshold current
1
5
mA
Input delay
250
ns
Digital Output:
Parameter
Min.
Typ.
Max.
Unit
Common VCC supply voltage (V
CC
- V
OUT
)
30
V
Output current, saturated operation: (V
CC
- V
OUT
) < 1 V
10
mA
Turn-On time (24 V common VCC, 10 mA)
5
µs
Turn-Off time (24 V common VCC, 10 mA)
15
µs
1