Camera Controls
Parameter
Trigger Noise Suppression Time
Minimum
0 s
Maximum
1 s
Default
0 s
USB3 Vision: GenICam
TriggerDenoise
Video4Linux2
Trigger Noise Suppression Time
VCD Property
VCDID_Trigger\VCDElement_TriggerDenoise
5.6
Digital I/O
The 33U series has one digital input and one digital output. The digital input can be
used as a
input but the current status can also examined directly.
The digital output can be configured as a
output to signal the exact moment
when the image sensor is sensitive to light so that external light sources can be
synchronized to its operation cycle.
5.6.1
General Purpose Input
The
General Purpose Input
parameter allows the current status of the
Parameter
General Purpose Input
True
TRIGGER_IN line status is low
1
False
TRIGGER_IN line status is high
0
USB3 Vision: GenICam
GPIn
Video4Linux2
GPIN
VCD Property
VCDID_GPIO\VCDElement_GPIORead
VCDID_GPIO\VCDElement_GPIOIn
5.6.2
General Purpose Output
The
General Purpose Output
parameter controls the status of the