Platinum™ VX
Installation and Operation Manual
Platinum VX Frame
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 1.2 | Page 25
Figure 7:
1 RU Platinum VX - Rear View Connectors
For more information on the PV-16X16-FR-1, see:
PV-16X16-FR-1 User Interface Platinum VX Dashboard (on page
PV-16X16-FR-1 Frame Contents Frame Specific Details (on page 95)
Main module in the frame PV-32x32 Modules (see "PV-32x32 Modules (1 RU and 1 RU CQS frames)"
on page 102)
1 RU Frame (PV-CQ16-FR-1) with Clean and
Quiet Switching
The
PV-CQ16-FR-1
is a clean and quiet version of the 1 RU Platinum VX, consisting of a 1 RU frame (PV-
FR-1), and an additional Clean and Quiet Switching (CQS) sub board (See PV-CQ16 Modules (CQS
Modules) (on page 104) )
Table 5:
1 RU PV-CQ16-FR-1 Platinum VX Frame Modules and Matrix
Part Number Frame
Type
HD-BNC
Inputs/Outputs
SFP Inputs/outputs
Total Matrix Size
PV-CQ16-FR-1 1 RU
18x18
12x12
18x18 (electrical only)
30x30 (electrical and SFP)
Frame Temperature
There are four fans on the PV-CQ16-FR-1 frame. The PV-CQ16 Modules (CQS Modules) (on page 104)
contain temperature sensors and report temperatures by Zone (Zone 1/2/3) in Celsius. If any of the
sensors report temperature over the predefined limit, an Alarm is triggered (Module Temperature is too
high) to alert the user who can then take appropriate actions such as powering off the frame to prevent
overheating.
For more details, see Clean and Quiet Switching (on page 66).