Platinum™ IP3
Installation and Operation Manual
Resource Module (PX-RES)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 47
Front Ethernet Ports
There is an Ethernet port on the front of each Resource Module (PX-RES). This Ethernet port can be used
for configuring each Resource Module. The default (hard coded) IP addresses are as follows:
Table 11:
Front Ethernet Ports
PX-RES 1 (Primary)
IP Address 1
169.254.3.126
IP Mask 1
255.255.255.0
Gateway Address 1
169.254.3.1
PX-RES 2 (Secondary)
IP Address 2
169.254.3.127
IP Mask 2
255.255.255.0
Gateway Address 2
169.254.3.1
Sync Ports
Each
PX-CBP
module includes four looping sync inputs. Each sync input automatically detects and locks
to NTSC, PAL, analog HD Tri-Level, or AES signals. The control system reports the presence and type of
sync signal detected on each of the four inputs. These synchronization signals are made available to and
are distributed by the Resource Modules to every crosspoint and output monitoring I/O module in the
frame.
Sync signals distributed from the Resource Module remain undisturbed when switching over to a
redundant Resource Module. In addition, Resource Modules automatically generate and distribute an
internal synchronization signal when no external sync input is present.
If needed, optional Sync Distribution Modules may be added to the frame to distribute external and
internal sync signals to all Input/Output modules. These Sync Distribution Modules also support
redundant operation, and have the capability to seamlessly switch over when the redundant module is
removed.