Platinum™ IP3
Installation and Operation Manual
1500 Watt Power Supply and External Power Supply Frame
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 275
ZONE 1
ZONE 2
Power Distribution Zones
The 28 RU Platinum IP3 frame (PX-FR-28) is divided into four 24V Power Zones and two 5V Power Zones,
to manage power distribution and loading within the frame. The 15 RU Platinum IP3 Frame (PX-FR-15) is
divided into two Zones.
For low power modules such as the PX-HSR9C-IBG or PX-HSR16C-OBG, 2N redundancy can be achieved
with a second PX-PS plugged into a Power Zone. For high power modules such as the HV-SXP-16x3 or PT-
FSDMX-IBG, redundancy may require the External Power Supply Frame (PX-FR-EXPS) depending upon
the number of modules plugged into that Power Zone.
Each PX-PS has a 24V and 5V output power rail. When a PX-PS is plugged into the IP3 frame or External
Power Supply Frame, its 24V output will connect to one of the four 24V power zones and its 5V output
one of the two 5V power zones.