Selenio
TM
BNP User Guide, Release 3.7.1
210
- DVB-CA Configuration
Setting Up an NTP Server
To enable proper interaction of the DVB-CA feature with the CAS, a network time protocol (NTP) server
must be set up in the
Element Manager
such that the IP Address of the NTP server is from the same
source as that used by the CAS.
Use the
Global
configuration tab page to set NTP parameters.
Menu Path
Access via
BNP Element Manager
Configuration
tab -> Global
tab screen.
1.
At the
Server 1
: field, type the IP address of the NTP server,
in dotted decimal format.
2.
Click the
Apply Configuration
button to save and use the
settings displayed in this tab page.
Configuring Ethernet Control Port for DVB-CA
Of the two 10/100 Base T Ethernet management ports on the BNP, only
Ethernet Port 2
is available for
management access to the CAS. However, you must configure an IP address for both Ethernet Port 1
and Ethernet Port 2 for proper DVB-CA functionality.
The ports you will configure at the
Element Manager
are mapped to the physical ports of the BNP as
shown in
Figure 148. DVB-CA - Ethernet Control Port mapping
10/100-1 -->
Ethernet Port 2
10/100-0 -->
Ethernet Port 1
Use the
Ethernet Control Port
tab page to configure the BNP control ports.
Menu Path
Access via
BNP Element Manager
Configuration tab -> Ethernet Control Port
tab
screen.
1.
In the
Ethernet Port 2
section, type the
IP Address, Subnet Mask, Gateway,
and
DNS Server
(optional) to which the CAS will connect.