12
DAC6800
+
BCA4 and DAC6800
+
BCA4Z Installation and Operation Manual
Chapter 2: Installation
Setting Jumpers ‘A’, ‘B’ and ‘C’ for Analog Level Options
Follow this procedure to set the analog level for the DAC6800
+
BCA4
or DAC6800
+
BCA4Z module:
1. Locate jumpers ‘
A
’, ‘
B
’
and ‘
C
’
on the module.
See
for the location of the jumpers.
2. Place jumpers on the pins according to
.
Figure 2-3.
Jumper Settings for 16 dBu (10 dBm)
Figure 2-4.
Jumper Settings for 18 dBu (12 dBm)
Note
Pin 1 is denoted by a 1 marking.
Table 2-3.
Analog Level Jumper Pin Settings
Analog Level
Jumper Setting
16 dBu (10 dBm)
No jumpers on pins (
See
18 dBu (12 dBm)
Jumper on pins 1 and 2 of ‘C’ (
See
20 dBu (14 dBm)
Jumper on pins 1 and 2 of ‘B’ (
See
22 dBu (16 dBm)
Jumper on pins 1 and 2 of ‘A’ (
See
.)
24 dBu (18 dBm)
Jumper on pins 2 and 3 of ‘A’ (
See
.)
26 dBu (20 dBm)
Jumper on pins 2 and 3 of ‘B’ (
See
28 dBu (22 dBm)
Jumper on pins 2 and 3 of ‘C’ (
See
3 2 1
3 2 1
3 2 1
Jumper ‘C’
Jumper ‘B’
Jumper ‘A’
1
1
1
3 2 1
3 2 1
3 2 1
Jumper ‘C’
Jumper ‘B’
Jumper ‘A’
1
1
1