2.0 Getting Started
The following points describe the set-up procedure:
•
Physically mount the sonar. Refer to Section 2.1 for details.
•
Ensure 24 VDC @ 1 A minimum power supply is off.
•
Configure the network card’s IP address (see Sections 3.4.2 and 3.4.1) or Comm port when using 881L
and 881A respectively.
•
Connect the RJ45 connector to the PC’s network port or cable to the PC’s Comm port (881L and 881A
respectively).
•
Plug the underwater connector to the sonar.
•
Deploy to stable, flat location.
•
Power up the 881A/L-GS.
•
Wait for gyro calibration to complete. The sonar, upon power up will calibrate the motor, delay for 30
seconds and automatically perform a gyro calibration. No communication to the gyro sub-system is
available at this time.
•
Launch the Win881AL_GS.exe program.
•
Verify the local latitude and declination setting (see Section 3.5.8) and adjust if necessary.