To drain the hydrotherapy spa, follow the steps below:

1. Using the console, adjust the temperature to the

lowest setting.

2. Shut off the power to the spa, at the circuit breaker

or GFCI.

3. Remove the pump access panel from the spa.
4. Pull the hose out and hold it above the waterline.

Remove the cap and attach a garden hose to the
drain hose. Lower the hose and drain the spa.

5. When the spa is empty, close the valve and

remove the garden hose. Re-attach the cap and
return the drain hose inside the spa. 

6. Re-attach the access panel.
7. Refill the spa and treat the water with chemicals

(see pages 10 and 14).

DRAINING THE PUMPS

After the hydrotherapy spa is drained, the jet pumps
should also be drained if the spa will be stored for
more than thirty days or if it may be exposed to freez-
ing temperatures.

Turn off the power to
the spa. To drain the jet
pumps, remove the
access panel from the
spa unit (see ATTACH-
ING AND REMOVING
THE ACCESS PANEL
on page 14). Locate
the jet pumps inside
the spa. Loosen the
indicated collar on
each of the pumps.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use.
If you decide to store the spa for the winter, store it in
a warm, dry location. Follow the steps below to winter-
ize the spa.

1. Make sure the power to the spa is turned off.
2. Drain the spa (see DRAINING THE HYDROTHER-

APY SPA on the previous page and this page).

3. Remove all remaining water from the spa shell. Dry

the spa shell with towels.

4. Set the air control to the lowest setting. Use a

wet/dry vacuum to pull any remaining water from
the system. To do this, place the vacuum nozzle
over each jet, starting with the highest jet and fin-
ishing with the lowest jet. 

5. Set the air control on the console to the highest

setting and repeat step 3.

6. Drain the pumps (see DRAINING THE PUMPS on

this page). Once the water is drained from the
pumps, place the vacuum nozzle over the drainage
hole in the pumps and vacuum any additional
water from the pumps. Note: For additional pro-
tection, remove the pump/motors from the spa
and store them in a climate-controlled room.

7. Clean the spa shell (see page 13).
8. Clean the filter (see page 13).
9. Shut the power off at the breaker. Label the

breaker in such a way that the breaker will not
be turned on accidentally.

10. Re-attach the access panel and the spa cover.

REPLACING THE LIGHT BULB

If the underwater light burns out, you will need to
remove the pump access panel to replace it (see
ATTACHING AND REMOVING THE ACCESS PANEL
on page 14). Make sure the spa power is turned off.
Next, locate the light housing. Turn the light housing
counterclockwise and remove it from the spa shell.

To replace the light bulb, pull the old light bulb out of
the housing and insert a new light bulb. Re-attach the
light housing to the spa shell. Re-attach the access
panel to the spa.

Collar

Drain

Hose

Cap

Light Housing

Light

Housing

Light

Bulb

Summary of Contents for IMSB62820

Page 1: ...e assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST Model No IMSB62820 IMSG62820 Serial No The serial number is on a plastic sign inside the spa behind the access pane...

Page 2: ...Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...njury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be serio...

Page 5: ...NING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted w...

Page 6: ...e spe cialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the RENEW 628 If you have addi tional questions please call our Customer Servic...

Page 7: ...spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you...

Page 8: ...that all parts are oriented as shown in the drawings Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING...

Page 9: ...cuit Interrupter GFCI installed in your home This procedure must be performed by a qualified licensed electrician A wiring diagram is found on the inside of the electronics package for reference Under...

Page 10: ...enance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the pump button on the console see USING THE CONTROLS on page 1...

Page 11: ...izes com bined chlorine and bromine freeing them to be con tinuously re used reducing the chemical needs and costs of the spa s sanitation H The console controls the spa jets turns the underwa ter lig...

Page 12: ...jets will run at high speed providing moderate pres sure hydrotherapy If the button is pressed again the jets will shut off The spa also features an automatic mode that heats and filters the water wh...

Page 13: ...d monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Use a non silicone bas...

Page 14: ...CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 to 5 hours Press the temperature up or temperature down button on the console When the display...

Page 15: ...PA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air control to the lowest setting Use a wet dry vacuum to pull any remaini...

Page 16: ...sing the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 6 to 8 hours 50 F to 70 F 9 to 11 hou...

Page 17: ...water has reached 112 F remove the spa cover to cool the water Overheating may occur if the filter cycle is set too long At 110 F the spa should reset itself If the high limit sensor detects 118 F at...

Page 18: ...30 2 Heater Gasket 31 1 Whirlpool Jet 32 1 Filter Housing Door 33 1 Face Plate Assembly 34 3 Panel 35 4 1 4 Lock Washer 36 1 Filter Housing 37 4 Medium Jet Housing 38 1 Console With Overlay 39 1 Large...

Page 19: ...37 31 25 39 52 41 40 6 7 8 26 27 15 18 28 28 6 6 6 34 14 9 9 30 30 29 38 13 19 21 24 20 13 48 45 23 47 53 50 41 43 17 17 20 46 35 35 46 49 49 4 36 5 22 3 10 16 32 33 EXPLODED DRAWING Model Nos IMSB62...

Page 20: ...ollowing incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting...

Reviews: