background image

18

Part List—Model No. IMSB61502/IMSG61502          

R0901A

1

1

Thermometer Fitting

2

2

Long Access Panel

3

3

Face Ring

4

4

Small Rotator

5

2

Short Access Panel

6

4

Pivot Ring

7

32

#10 x 2” Sheet Metal Screw

8

1

Filter Cover

9

8

Wood Screw

10

3

Medium Jet Housing 

11

1

Spa Cover

12

2

Small Nozzle

13

2

Jet Pump/Motor O-ring

14

1

Electronics Package*

15

1

Skimmer Housing*

16

1

Filter

17

2

#8 x 1/2” Screw

18

2

Suction Cover

19

7

Jet Ring

20

1

Jet Pump/Motor

21

1

Jet Pump/Motor Power Cord

22

2

Nozzle Bushing

23

3

Medium Nozzle

24

1

Overlay

25

4

Corner Panel

26

5

Jet Housing

27

1

Drain Plug

28

1

Drain Plug O-ring

29

4

Rubber Washer

30

4

Buckle

31

8

#4 x 3/4” Screw

32

4

Flared Nozzle

33

1

Filter Cover O-ring

34

2

Air Control Knob

35

1

Cover Ring

36

3

Nozzle Housing

37

4

Nozzle Retainer Ring

38

4

1/4” Washer

39

1

Rotator

40

1

Light Cover, Red

41

1

Light Cover, Blue

42

1

Diverter

43

1

Basket

44

1

Filter Door

45

10

#8 1 1/2” Screw

46

1

Hose Washer

47

1

Diverter Valve

48

1

Trim Plate

49

1

Foam Weir

50

1

Hose Cap

51

1

Console with Overlay

52

2

Gaskets

53

1

Large Rotary Jet

#

1

Ground Wire

#

2

Buckle Key

#

1

User’s Manual

#

1

Large Warning Sign

#

1

Warning Sign

#

1

Light Bulb

#

1

Motor Board

#

3

Pillow

#

1

Filter Housing

* Indicates a part that is serviceable only by service

technicians.

# Indicates a non-illustrated part.

Specifications are subject to change without notice.

Key No. Qty.

Description

Key No. Qty.

Description

15*

40

41

50

46

44

49

48

47

42

43

45

Summary of Contents for IMSB61502, IMSG61502

Page 1: ...diate assis tance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this man...

Page 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...njury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be serio...

Page 5: ...ll users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on th...

Page 6: ...to feel your best For your benefit read this manual carefully before using the RENEW 615 If you have questions after reading the manual call our Customer Service Department toll free at 1 877 897 749...

Page 7: ...spa provided that you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...etal metal water pipes or conduit within five feet of the spa 1 Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two pages Rem...

Page 9: ...tronics package as a reference Under no circumstances should the spa be wired by someone other than a qualified electrician Before you have the spa wired make sure that it is in the desired position a...

Page 10: ...g proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE...

Page 11: ...hem F The two fixed jets are always on G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone provides a way to help sanitize the spa with minimal chemical treatme...

Page 12: ...ter The temperature can be set between 80 F and 104 F The water heats at about 6 F per hour with the cover on Use a medical or other accu rate thermometer to check the temperature of the water Note Th...

Page 13: ...p solution do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water an...

Page 14: ...sting and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 5 hours Press the temp up or temp down button on...

Page 15: ...1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the lowest...

Page 16: ...main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See th...

Page 17: ...MPTOM NO AIR FLOWS THROUGH THE ADJUSTABLE HYDROTHERAPY JETS WHEN THE AIR CONTROL IS TURNED COUNTER CLOCKWISE a If no air flows through the hydrotherapy jets when the air control is turned counterclock...

Page 18: ...Washer 30 4 Buckle 31 8 4 x 3 4 Screw 32 4 Flared Nozzle 33 1 Filter Cover O ring 34 2 Air Control Knob 35 1 Cover Ring 36 3 Nozzle Housing 37 4 Nozzle Retainer Ring 38 4 1 4 Washer 39 1 Rotator 40 1...

Page 19: ...6 1 26 30 31 14 21 27 28 13 20 11 7 2 7 5 25 25 25 16 3 26 26 10 18 17 9 9 33 13 9 38 38 38 38 29 29 29 4 6 19 23 36 39 35 32 37 12 3 19 22 18 19 24 51 52 52 Exploded Drawing Model No IMSB61502 IMSG61...

Page 20: ...llowing incidents any damage to the cedar surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting fro...

Reviews: