The RENEW 815 is designed for up to three adults.
The RENEW 815 holds 268 gallons of water and
offers an automatic, programmable heating (70¡F to
104¡F) and filtration system. 

The guidelines below explain how to properly use the
RENEW 815. Follow these guidelines to maintain the
RENEW 815 for your long-term enjoyment.

PRIMING THE SPA JET UNIT

The water pump in the spa jet unit must be primed
before you use the RENEW 815 the first time. You
must also prime the pump before using the unit each
time you re-fill the RENEW 815, and each time the fil-
ter is cleaned.

To prime the spa jet
unit, install the provided
jet plugs into the four
hydrotherapy jets.
Remove the filter cap.
Fill the filter housing
with water. Note: Leave
the filter in the housing
while filling with water.
Replace and tighten the
filter cap tightly.
Remove the jet plugs
and store them in the
pouch inside the cover.

IMPORTANT: The spa
jet unit may be seri-
ously damaged if the
pump is not properly
primed, or if the filter cap is not replaced and fully
tightened. 

PLUGGING IN THE RENEW 815 

Once the RENEW 815 is filled with water up to the fill
line, and the pump has been primed, the power cord
can be plugged in and the spa jet unit can be turned
on. Note: The first time the power cord is plugged in,
the spa jet unit will turn on automatically after a 5 to 10
second delay.

When connecting the power cord, plug the power cord
directly into a grounded circuit capable of carrying 15
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately, if it
becomes damaged.

The power cord is equipped with a Ground Fault
Circuit Interrupter (GFCI), located at the end of the

power cord. You should always test the GFCI before
using the RENEW 815.  

First, turn on the RENEW 815 by pressing the power
button on the console. Once the unit is running, press
the GFCI ÒtestÓ button. The RENEW 815 should shut
off. Press the ÒresetÓ button. The RENEW 815 should
resume normal operation. If the RENEW 815 contin-
ues to run after the ÒtestÓ button is pressed, then the
GFCI is damaged. Do not use the RENEW 815 until
the GFCI has been repaired or replaced by a qualified
electrician.

STARTING THE RENEW 815 

Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Turn the console on
(see USING THE CONSOLE on the next page). The
pumping unit will heat the water as it pumps. Cover
the RENEW 815 with the spa cover. 

The spa cover

must be tight.

The temperature can be set or changed by the control
on the console (see USING THE CONSOLE on page
12).

TESTING AND TREATING THE WATER

The RENEW 815 comes with a starter chemical pack
for maintaining the water in the spa. Disregard the
directions on the individual packages of ÒQUICK pHix
It DOWNÓ and ÒQUICK pHix It UP.Ó However, the
directions on the bottle of ÒNon-chlorine ShoxÓ and
ÒBromine BaseÓ are correct. 

Always keep the chemi-

cals away from children and pets.

The first time you use the spa, you should test and
treat the water. Once you have verified that the spa
jet unit is functioning properly, and have allowed the
water to circulate for a while, you should remove the
spa cover and add 1/3 of the ÒBromine BaseÓ bottle,
and 1/3 of the ÒNon-chlorine ShoxÓ bottle to the water

Test and Reset

Buttons

Grounded circuit capable of

carrying 15 or more amps

GFCI

Filter

Cap

Jet

Plugs

Using the Hydrotherapy Spa

Summary of Contents for IMHS81590

Page 1: ...OMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST Model No IMHS81590 Ser...

Page 2: ...d in the center of this manual 2 Table of Contents The decals shown below have been placed on the RENEW 815 If a decal is missing or if it is not legible please call our Customer Service Department to...

Page 3: ...gned to support weight 11 Remove any water that may collect on the spa cover 12 Keep children and pets away from the RENEW 815 when it is not in use 13 Keep all chemicals away from children and pets 1...

Page 4: ...child could be seriously harmed 27 DANGER To reduce the risk of drowning Prolonged immersion in the RENEW 815 may cause hyperthermia a dangerous condition which occurs when the internal body temper a...

Page 5: ...rvice Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please note the product model number and serial number befor...

Page 6: ...r of the tub is 63 You should allow for this size plus the size of the spa jet unit plus room to remove the cover when choosing the location 8 Be sure to note any other considerations such as aestheti...

Page 7: ...edge of the wood surround see drawing 1B Make sure that you pull the flap tight as you go around Start the flap where the fastener strip starts Make sure all three holes in the Inflatable Liner are v...

Page 8: ...he large holes in the Inflatable Liner 29 Push a Wet Side Gasket 48 onto each con nector Thread a Wet Side Nut 49 onto each con nector and make sure it is tight 4 Position the wet side jet pack B as s...

Page 9: ...ut make sure you smooth out as many wrinkles as possible from the sides and the bottom of the Liner When most of the wrinkles are gone keep filling the spa until the water reaches the fill line Do not...

Page 10: ...e power cord is equipped with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord You should always test the GFCI before using the RENEW 815 First turn on the RENEW 815 by pre...

Page 11: ...t is tight while the water is heating The chart below shows approximate heating times for different air tem peratures with a water temperature of 60 to 64 F SECURING THE SPA COVER The spa cover can be...

Page 12: ...unscrewed and the unit must be tipped on its side Rock the spa jet unit slightly until all the water has drained from the pump Replace the nut on the pump Replace the dry side shell filter cap and pi...

Page 13: ...5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add the chemicals to the water as directed 7 Always store chemicals in a cool dry place 8 Always keep ch...

Page 14: ...ing the water should heat Cover the RENEW 815 with the spa cover The spa cover must be tight The water will heat at a rate of 1 3 F an hour If you are using the spa indoors and the room tem perature i...

Page 15: ...ept outdoors in cold weather you must allow the spa to maintain a safe temperature by running in automatic mode Allowing the spa jet unit to freeze will damage the unit If you do not want to use the s...

Page 16: ...mages caused by or attributable to the following incidents any dam age to the wood exterior resulting from improper maintenance or any damage to the wood or tile exterior attributable to freight misha...

Page 17: ...e 1 to 3 days depending on the room temperature to heat the water in the spa The good news is that once the water is heated it will maintain its temperature for a relatively low cost You can reduce th...

Page 18: ...low 27 4 Jet Plug 28 1 Tail Piece Assembly 29 1 Inflatable Liner 30 1 Temperature Probe Assembly 31 1 On Off Wire Harness 32 1 On Off Switch Assembly 33 2 1 4 Nylon Locknut 34 1 3 1 Wire Harness 35 2...

Reviews: