background image

14

3. Do not exceed the recommended amounts of

chemicals—follow the directions on the label.

4. Keep all chemicals out of the reach of children

and pets.

5. Keep all containers closed tightly when not in

use.

6. Never add water to the chemicals—always add

the chemicals to the water as directed.

7. Always store chemicals in a cool, dry place.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of the relative acidity or

alkalinity in the water, and is measured on a scale of

1 to 14. Pure water has a value of 7, which is neutral.

Any value above 7 is alkaline, and any value below 7

is acidic. You should maintain a slightly alkaline pH

level, between 7.2 and 7.8, in the hydrotherapy spa.

Severe problems can occur when the pH balance is

not maintained within this range. If the pH level

exceeds 7.8, dissolved minerals can build up and clog

the plumbing in the spa jet unit. If the pH level falls

below 7.2, the acid level in the water will begin to cor-

rode the metal parts in the spa jet unit. Also, the sani-

tation agents in the water will not be effective if the pH

level is not properly maintained. Damage caused by

improper pH levels is not covered under the warranty.

To maintain the proper pH level, test the pH of the

water regularly. To test the water, purchase a pH test

kit at a pool and spa supply store. The pH reading

should be between 7.2 and 7.8. If the level is too low,

add a pH increaser (usually soda ash). If the level is

too high, add a pH reducer (usually sodium bisulfate).

Test the water again after five minutes. See the

instructions with your pH test kit for additional infor-

mation about testing and adjusting the pH.

SANITIZING THE HYDROTHERAPY SPA

The most common sanitizing agent is a solid bromine

concentrate. The amount required varies according to

several factors, such as user load, temperature, and

water conditions. Proper water maintenance is a com-

plex process. Contact your local pool and spa supplier

for information concerning which chemicals you

should use in your area to sanitize the spa.

CHANGING THE FILTER CYCLE

The spa will filter the water every 12 hours. The dura-

tion of the cycle can be adjusted to last 2 to 5 hours.

Press the temperature up or temperature down button

on the console. When the display begins to flash,

press the pump button. The display will read F2. To

change the time, press the temp up button until the

desired time is reached. Press the pump button to

confirm the selection. As spa usage increases, the

duration of the filter cycle may need to be increased.

ATTACHING AND REMOVING THE ACCESS PANEL

Turn off the spa power. To remove the indicated

Access Panel (25), Remove the four 1/4” x 1 1/2”

Machine Screws (46) that secure the Access Panel to

the spa. Carefully remove the Access Panel and set it

aside.

To replace the Access Panel, hold the Access Panel

in place and secure it with the 4 1/4” x 1 1/2” Machine

Screws (46).

Be careful not to overtighten the

Screws.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four

times per year and refilled with clean water. You may

need to drain the spa more often, depending on the

user load. This must be done because after repeated

chemical treatment the water becomes chemically

saturated. Once this happens, additional chemical

treatment of the water is no longer effective. The spa

should also be drained if you will not be using it for

long periods of time. The spa must always be drained

before major repairs are made.

The hydrotherapy spa should always be covered

when it is empty. Direct sunlight can cause exten-

sive damage. The surface of the spa shell can

reach temperatures as high as 150°F in a matter

of minutes if exposed to the sun while it is empty.

These high temperatures can cause significant

damage, such as blistering of the shell surface

and warping of the spa shell. Any damage caused

by sun exposure is not covered under warranty.

25

46

46

Summary of Contents for IMSB73920

Page 1: ...provide immediate assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST Model No IMSB73920 IMSG73920 Serial No The serial number is on a sign behind the access panel Writ...

Page 2: ...Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users...

Page 3: ...nt damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa t...

Page 4: ...eir physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important du...

Page 5: ...SE INSTRUCTIONS water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the...

Page 6: ...your best For your benefit read this manual carefully before using the IMAGE RENEW 739 If you have ques tions after reading the manual please call our Customer Service Department toll free at 1 877 89...

Page 7: ...the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...s Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included One phillips screwdriver A wire c...

Page 9: ...gh or low positions 4 The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt Ground Fault Circuit Interrupter GFCI installed in your home This procedure must...

Page 10: ...proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE C...

Page 11: ...ce G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone helps sani tize the spa with minimal chemical treatment H The console controls the spa jets turns the und...

Page 12: ...mode that heats and filter the water when the spa is left unattended When the power to the spa is first turned on or if the water temperature is below the set temperature the water will be heated as r...

Page 13: ...spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the en...

Page 14: ...Proper water maintenance is a com plex process Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa CHANGING THE FILTER...

Page 15: ...the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air controls to the lowest settin...

Page 16: ...the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the w...

Page 17: ...ce the damaged seal b Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the hydrotherapy spa the spa shell may have a leak Contact y...

Page 18: ...ew 28 8 1 4 x 1 1 2 Screw 29 1 Console With Overlay 30 1 Whirlpool Jet 31 8 1 4 Washer 32 1 Face Plate Assembly 33 3 Panel 34 2 Heater Collar With Screw 35 1 Volcano Jet 36 3 Nozzle Housing 37 21 Smal...

Page 19: ...8 23 31 13 20 1 12 2 15 37 43 44 36 40 39 41 42 41 38 35 46 46 46 46 33 6 6 9 47 45 48 45 48 14 9 9 30 52 50 50 17 17 17 17 53 53 23 31 49 4 23 31 23 31 4 7 8 34 34 54 51 5 22 3 21 16 24 32 Exploded D...

Page 20: ...e following incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulti...

Reviews: