background image

15

To drain the hydrotherapy spa, follow the steps below:

1. Using the console, adjust the temperature to the

lowest setting.

2. Shut off the power to the spa, at the circuit breaker

or GFCI.

3. Remove the pump access panel from the spa.

4. Remove the end of the drain hose from the spa.

Remove the cap and attach a garden hose to the

drain hose.

5. Open the valve by turning the valve knob. The

water will begin to drain.

6. When the spa is empty, close the valve and

remove the garden hose. Reattach the cap and

return the drain hose to the clip inside the spa.

7. Reattach the access panel.

8. Refill the spa and treat the water with chemicals

(see pages 10 and 14).

DRAINING THE PUMPS

After the hydrotherapy

spa is drained (see

DRAINING THE

HYDROTHERAPY SPA

on page 14), the jet

pumps should also be

drained if the

hydrotherapy spa will

be stored for more than

thirty days or if it may

be exposed to freezing temperatures.

Turn off the power to the spa. To drain the jet pumps,

remove the access panel from the spa unit (see

ATTACHING AND REMOVING THE ACCESS PANEL

on page 14). Locate the jet pumps inside the spa unit.

Remove the drain plugs from the jet pumps and allow

all water to drain out. Replace the drain plugs.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use.

If you decide to store the spa for the winter, store it in

a warm, dry location. Follow the steps below to winter-

ize the spa.

1. Make sure the power to the spa is turned off.

2. Drain the spa (see DRAINING THE HYDROTHER-

APY SPA on the previous page and this page).

3. Remove all remaining water from the spa shell. Dry

the spa shell with towels.

4. Set the air controls to the lowest setting. Use a

wet/dry vacuum to pull any remaining water from

the system. To do this, place the vacuum nozzle

over each jet, starting with the highest jet and fin-

ishing with the lowest jet.

5. Set the air controls on the console to the highest

setting and repeat step 3.

6. Drain the pumps (see DRAINING THE PUMPS on

this page). Once the water is drained from the

pumps, place the vacuum nozzle over the drainage

hole in the pumps and vacuum any additional

water from the pumps.

Note: For additional pro-

tection, remove the pump/motors from the spa

and store them in a climate-controlled room.

7. Clean the spa shell (see page 13).

8. Clean the filter (see page 13).

9. A licensed, qualified electrician should disconnect

the power from the 240-volt power source.

10. Reattach the access panel and the spa cover.

REPLACING THE LIGHT BULB

If the underwater light burns out, you will need to

remove the pump access panel to replace it (see

ATTACHING AND REMOVING THE ACCESS PANEL

on page 14). Make sure the spa power is turned off.

Next, locate the light housing. Turn the light housing

counterclockwise and remove it from the spa shell.

To replace the light bulb, pull the old light bulb out of

the housing and insert a new light bulb. Reattach the

light housing to the spa shell. Reattach the access

panel to the spa.

Drain Plug

Drain

Hose

Valve

Knob

Cap

Light Housing

Light

Housing

Light

Bulb

Summary of Contents for IMHS63103

Page 1: ...ovide immediate assistance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST Model No IMHS63103 IMHS63104 Serial No The serial number is on a plastic sign behind the acces...

Page 2: ...Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users...

Page 3: ...nt damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa t...

Page 4: ...ir physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important dur...

Page 5: ...herapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on the decals WARNING Read...

Page 6: ...feel your best For your benefit read this manual carefully before using the hydrotherapy spa If you have questions after reading this manual call our Customer Service Department toll free at 1 877 897...

Page 7: ...spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you...

Page 8: ...Y REQUIRES THE FOLLOWING TOOLS not included One 1 phillips screwdriver You may also need a small amount of soapy water A wire connector is provided on the electronics pack of the spa to connect a mini...

Page 9: ...e knob on top of the drain hose and make sure that the cap is fully tightened 4 The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 40 amp Ground Fault Circuit Int...

Page 10: ...aintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE CON TROLS on pa...

Page 11: ...ght opera tion see USING THE CONTROLS on page 12 J The four suction intakes near the floor of the spa bring water into the pumps in order to operate the system Never operate the spa without the suc ti...

Page 12: ...the left on and off If the button is pressed once the jets will run providing soothing hydrotherapy If the button is pressed again the jets will shut off The spa also features an automatic mode that...

Page 13: ...pa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the enti...

Page 14: ...mation about testing and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 1 to 6 hours Press the temp up or te...

Page 15: ...e the power to the spa is turned off 2 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels...

Page 16: ...take approximately 6 to 8 hours for the water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the appro...

Page 17: ...adjustable hydrotherapy jets can be closed and opened by turning the jet faces If no air flows through the hydrotherapy jets when the air control is turned counterclockwise turn the jet faces counterc...

Page 18: ...32 2 Medium Jet Housing 33 1 Whirlpool Control Knob 34 2 Air Control Knob 35 2 Nozzle Housing 36 4 Small Rotator 37 1 Large Rotary Jet 38 1 Face Ring 39 6 9 Fixed Jet 40 5 Jet Ring 41 1 Adjustable Pu...

Page 19: ...13 4 50 24 13 19 19 44 32 36 12 26 35 6 29 43 42 38 40 22 22 40 44 34 53 52 52 24 51 51 23 23 23 23 24 51 51 14 54 24 9 24 24 50 51 57 55 50 51 56 24 24 57 57 10 39 39 41 48 59 18 21 20 59 18 59 18 59...

Page 20: ...e to the following incidents any damage to the surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resultin...

Reviews: