Imacon Flextight Progression UserÕs Guide
Hardware ReferenceÑFlextight Progression
Changing the Light Tubes
33
English
The Light Table Tube
1.
Unplug the scanner from your wall socket.
2.
Swing down the lower-front panel by grabbing the opening for the
ßatbed working light (shown in Figure 2) and pulling forward.
3.
The light table tube is located directly behind the panel indicated in
Figure 9. It is held in place by two socketsÑone at each end of the
tube. Grab this tube by each end and gently pull it out of its sock-
ets.
4.
Mount a new tube into the sockets inside the scanner. Press the
new tube into the sockets by applying pressure at each end of the
tube, never at the middle.
5.
Close the lower-front panel.
Figure 9: Location of the light table tube
The light table
tube is located
behind this panel
and is accessible
by reaching up
under the panel.