Page 1: ...RANGECOOKER INSTALLATION MANUAL ROMA MILANO MAJESTIC ROMA MAJESTIC MILANO 06 07 08 09 10 12 15 INSTALLATION AND MAINTENANCE EN cod EI33960030000EN 32 2019 ZONA PER TARGHETTA ...

Page 2: ...2 ...

Page 3: ...t ELECTRICAL CONNECTIONS Groups of cooking Induction cookers GAS INSTALLATION GAS CONNECTIONS By the Qualified installer LPG CONVERSION Replacement of the injectors for all models ADJUSTMENT Adjustments minimun GAS flow KITCHEN TABLE ROMA MILANO MAJESTIC ROMA MAJESTIC MILANO WIRING DIAGRAM Key INDEX 4 5 5 5 6 7 8 8 9 9 10 10 11 11 12 12 13 14 14 ...

Page 4: ...pected accessories Verify the correct utilization of the appliance use of the oven thermostat and igni tion of the burners Suggest to note the serial number and warranty information Request that a periodic maintenance service has to be carried out at least every two years to maintain a fully functioning appliance In the case of leaking gas close the main gas tap and disconnect the product from the...

Page 5: ...oes not need to be joined to an exhaust system for combustion waste however ILVE strongly recommend that it is installed under a range hood or other smoke extraction system in compliance with the gas safe regulations The knowledge and consultation of the standards are a key factor for a qualified technician Indicatively the amount of air necessary for burner combustion is 2 m3 h for each KW of nom...

Page 6: ... top B The extractor hood must be installed in the way indicated in its instructions booklet and always at a minimum distance of 650 mm from the top of the hob C If the cooker is installed under a wall unit the minimum distance between this unit and the worktop must be 700 mm INSTALLATION Installation of the cooker Positioning of the appliance between furniture Min 50 mm Min 650 mm Min 700 mm G E ...

Page 7: ... back cross bar picture 5 and add 15mm Fix the supporting bracket in the centre of the cooker aperture on the supporting wall Check that the cooker is tight against the back wall to avoid tipping The anti turnover system is assured only if the cooker is installed with the back tight against the back wall INSTALLATION How to install the fixing bracket ...

Page 8: ...d see dataplate the power supply should be earthed as per the current regulations The appliance is supplied with a cable but without a plug the connection must be made taking into account that the green yellow cable is the earth conductor and it must never be interrupted The main cooker switch must be visible and easily reachable so that the appliance can easily be disconnected It is necessary tha...

Page 9: ...PPLY CONNECTION CABLE SECTION CABLE TYPE Mod P I06 230V a c 1P N 50 60 Hz 1 phase N 3x4 H05RR Mod P I09 M I09 230V a c 1P N 50 60 Hz 1 phase N 3x6 H07RN Mod PDI09 230V a c 1P N 50 60 Hz 1 phase N 3x6 H07RN Mod MDI10 230V a c 1P N 50 60 Hz 1 phase N 3x10 H07RN Mod PDI10 230V a c 1P N 50 60 Hz 1 phase N 3x10 H07RN ILVE Gas Cooker installation Due to confined space available at the rear of the cooker...

Page 10: ...ead sealing materials may be used as long as they are suitable for gas connections b CLASS for LPG installation The cooker must be installed according to LPG gas safe regulations The LPG conver sion must be carried out by a competent technician as per the instructions manual The appliance is delivered to operate as indicated on the label on the appliance CAT II2H3 GAS G20 mbar GAS G30 31 30 37 mba...

Page 11: ...or the new gas according to table number 2 on page 20 DCC Dual burners unscrew the 2 screws P and remove cover C fig 2 unscrew injectors U using a 7 mm spanner fig 3 fig 4 and replace them with those for the new gas according to table number 1 below 13 LPG CONVERSION Replacement of the injectors for all models 2 1 3 4 U U U ...

Page 12: ...he right to decrease it 5 If a liquid gas is used Butane Propane the regulating screw must be fully screwed in 1 Remove the bottom shelf of the oven 2 Light the burner and leave it at maximum for about 10minutes with the oven door closed 3 Turn the knob to minimum and still with the door closed check whether the flames have lowered but are still burning steadily about 3 4 mm 4 Remove the knob of t...

Page 13: ...4 0332 G25 20 mbar 1 05 0210 1 37 0332 1 42 0222 1 57 0332 0 72 0306 1 64 0332 1 30 0222 1 48 0332 G25 25 mbar 0 98 0210 1 26 0332 1 35 0222 1 50 0332 0 75 0306 1 50 0332 1 25 0222 1 40 0332 G2 350 13 mbar 1 26 0210 1 64 0332 1 64 0332 2 10 1048 0 91 210 2 10 1048 1 70 0222 1 90 0332 G25 1 25 mbar 0 98 0210 1 25 0309 1 28 0332 1 52 0332 0 71 0306 1 52 0332 1 25 0222 1 43 0332 G25 3 25 mbar 0 94 02...

Page 14: ...Temperature probe P Timer Programmer P Timer Clock P1 6 Induction hotplate PE Electric hotplate PT1000 Temperature probe R1 Upper heating element R2 Lower heating element R3 Grill heating element R4 Circular heating element R5 Barbecue heating element R6 Fryer heating element RE Energy regulator S1 Oven warning light S2 Mains power warning light S3 Grill warning light S4 Cooling fun warning S5 Bar...

Page 15: ...15 HOB GAS BASIC INDUCTION HOB AREA 5 WIRING DIAGRAM MA MA MA MA MA MA MA 11 AA SPL 66 11 11 66 o o o o F N ...

Page 16: ...16 WIRING DIAGRAM P09I E3 INDUCTION HOB AREA 4 ...

Page 17: ...17 INDUCTION HOB AREA 5 INDUCTION HOB AREA 6 WIRING DIAGRAM ...

Page 18: ...18 WIRING DIAGRAM P 06 07 30 08 09 E3 M 07 30 09 E3 ...

Page 19: ...19 WIRING DIAGRAM M09I E3 M12 E3 ...

Page 20: ...20 WIRING DIAGRAM M12I E3 M15 E3 ...

Page 21: ...21 MD10 E3 MD10I E3 WIRING DIAGRAM WIRING DIAGRAM ...

Page 22: ...22 WIRING DIAGRAM WIRING DIAGRAM P12 IE3 P12 E3 ...

Page 23: ...23 P15 PD12 E3 PD 09 10 I E3 WIRING DIAGRAM ...

Page 24: ...24 PD 09 10 E3 WIRING DIAGRAM ...

Page 25: ...25 ...