CORRECT POSITIONING
The hood should be placed at a minimum distance of
65 cm for the wall-mounted models and 75 cm
for the island/roof models. It could be that Your
specific hob requires the range hood to be placed at a
greater distance: always refer to the manufacturer’s in-
structions handbook for further information.
The installation site must:
- be well ventilated and not exposed to weather condi-
tions;
- Have a temperature b16 e i +32 °C
(90°F) and an humidity below 60% (any variation from
the aforementioned values could accelerate the usual
decay time of the carbon filters decay or limit the overall
performance of the hood);
--comply with all the applicable regulation from the User’s
country in terms of indoor air quality, electrical system
security and work safety;
- be suitable for the preparation of food.
For correct installation, refer to the drawings on
page 18 to 26.
The equipment must be installed in a way that
ensures easy access to electric connections.
Do not use any electric wire or other electric devices
to extend the original power cord. Please inspect the
existing wall sockets or power cords of your kitchen and
place the hood accordingly;
The fastening kit (screws and plugs) supplied with
the hood can only be used on masonry wall. For
installation on other types of walls consider alter-
native fastening systems, taking into account the strength
of the wall and the weight of the hood.
Do not place the equipment near flammable
materials or flammable substance containers
(e.g. partition walls, gas cylinders, etc.), to
avoid fire hazards.
All the installation operations, assembly, con-
nection to the electric power supply and extra-
ordinary maintenance must only be carried out
by qualified personnel, authorised by the Distri-
butor or Manufacturer, in accordance with the
legal requirements of the country of installation and in
compliance with equipment and workplace safety regu-
lations.
The equipment must only be installed by responsible and
experienced adults, without physical impairment
and in perfect psychological and physical con-
dition.
During installation, anyone and any objects not
involved in the assembly operations must be kept
away from the area.
Before starting the assembly operations, make
sure that all the necessary tools are available
and in good working order.
ELECTRIC CONNECTION
The electric connection can only be carried out by qua-
lified personnel (electrician).The cable and the internal
hood cables must
not be replaced or modified.
Before connecting the equipment to the power
mains:
- read the safety instructions provided at the
beginning of this manual;
- make sure that the electric system installed complies
with
the local regulations of the country of installation;
- make sure that the electric system installed is suitable
for the characteristics of the equipment being installed
(see the details on the data plate).
Refer to chapter “How to read product label” on
page 29 for further information on the data plate.
The equipment is supplied with the power supply
cable already attached: connect a suitable plug
for the load to the cable (the plug must comply with cur-
rent standards).
Remember the following:
- yellow- green cable: earth;
- blue cable: neutral;
- brown cable: phase.
Always install a circuit breaker for quick discon-
nection.The earth cable must be not interrupted
by the circuit breaker.
If the power cord is faulty, it should be replaced with
another one with identical features. To prevent all kinds of
risks, such replacement must be carried out by the Ma-
nufacturer, its technical support service, or in any case
by a similarly qualified individual. The Manufacturer is not
liable for any damage resulting from the use of unautho-
rized or aftermarket spares.
Before any interventions inside the hood, disconnect the
electric power supply.
Avoid winding the cable on itself if too long. Make
sure that the cable is not in contact with liquids,
sharp or hot objects (temperatures exceeding
>70°C ), or corrosive substances.
INSTALLATION
Summary of Contents for AGQ100
Page 2: ......
Page 19: ...19 INSTALLER INSTALLATION STEP 2 STEP 3 2 1 1000 MM 4023 64 min 1000 MM 4023 64 min ...
Page 20: ...20 INSTALLATION STEP 4 STEP 5 1 2 1 ø8 mm ø 05 16 1000 MM 40 23 64 min 1000 MM 40 23 64 min ...
Page 21: ...21 INSTALLER INSTALLATION STEP 6 STEP 7 1 3 4 2 ø8 mm ø 05 16 40 mm 137 64 ...
Page 22: ...22 INSTALLATION STEP 7 STEP 8 ...
Page 23: ...23 INSTALLER INSTALLATION STEP 9 STEP 10 2 1 150 mm 5 29 32 min 3 2 1 3 4 ...
Page 24: ...24 INSTALLATION STEP 11 2 3 4 1 ø8 mm ø 05 16 40 mm 137 64 STEP 12 ...
Page 25: ...25 INSTALLER INSTALLATION STEP 13 1 2 STEP 14 ...
Page 26: ...26 INSTALLATION STEP 15 STEP 16 2 1 ...
Page 32: ......