5-5
L4903EA
11. Cut-off Adjustment
Purpose:
To adjust the beam current of R, G, B, and
screen voltage.
Symptom of Misadjustment:
White color may be
reddish, greenish or bluish.
Note:
Screen Control FBT --- Main CBA
FBT = Fly Back Transformer
Use service remote control unit
1. Degauss the CRT and allow CRT to operate for 20
minutes before starting the alignment.
2. Input the Black Raster Signal from RF Input.
3. Enter the Service mode. (See page 5-1.)
4. Press [VOL
p
] button on the service remote
control unit and select “C/D” mode. (Display
changes “C/D”, “7F”, “VIDEO”, “AV MEMO”,
“STABLE SOUND”, “300”, “YUV MEMORY”, and
“NO SIG BRT” cyclically when [VOL
p
] button is
pressed.) then press “1.” The display will
momentarily show “CUT OFF R” (R= Red). Now
there should be a horizontal line across the center
of the picture tube. If needed gradually turn the
screen control on the flyback, clockwise until the
horizontal line appears. Adjust the Red Cut off by
pressing [CH
o
/
p
] buttons. Proceed to Step 5
when the Red Cut off adjustment is done.
5. Press [2] button. The display will momentarily
show “CUT OFF G” (G = Green). Adjust the Green
Cut off by pressing [CH
o
/
p
] buttons. Proceed to
step 6 when the Green Cut off adjustment is done.
6. Press [3] button. The display will momentarily
show “CUT OFF B” (B = Blue). Adjust the Blue cut
off by pressing [CH
o
/
p
] buttons. When done
with steps 4, 5 and 6 the horizontal line should be
pure white if not, then attempt the Cut off
adjustment again.
12. White Balance Adjustment
Purpose:
To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment:
White becomes bluish
or reddish.
Note:
Use service remote control unit
1. Operate the unit more than 20 minutes.
2. Face the unit to east. Degauss the CRT using
Degaussing Coil.
3. Input the White Raster (APL 100%).
4. Set the color analyzer to the CHROMA mode and
after zero point calibration, bring the optical
receptor to the center on the tube surface (CRT).
5. Enter the Service mode. (See page 5-1.) Press
[VOL
p
] button on the service remote control unit
and select “C/D” mode. (Display changes “C/D”,
“7F”, “VIDEO”, “AV MEMO”, “STABLE SOUND”,
“300”, “YUV MEMORY”, and “NO SIG BRT”
cyclically when [VOL
p
] button is pressed.) then
Press [8] button on the service remote control
Unit.
6. Press [4] button on the service remote control unit
for Red adjustment. Press [5] button on the
service remote control unit for Blue adjustment.
7. In each color mode, Press [CH
o
/
p
] buttons to
adjust the values of color.
8. Adjusting Red and Blue color so that the
temperature becomes 9200K (x: 286 / y: 294)±3%.
Test Point
Adj. Point
Mode
Input
---
Screen-Control
[CH
o
/
p
]
buttons
RF
Black
Raster
Tape
M. EQ.
Spec.
---
Pattern
Generator
See Reference
Notes below.
Figure
Fig. 2
Pattern Generator
Ext. Input
Test Point
Adj. Point
Mode
Input
Screen
[CH
o
/
p
]
buttons
RF
White
Raster
(APL
100%)
Tape
M. EQ.
Spec.
---
Pattern
Generator,
Color analyzer
See below
Figure
Fig. 3
Color Analyzer
Summary of Contents for IWT3206
Page 1: ...SERVICE MANUAL 32 ANALOG DIGITAL COLOR TELEVISION IWT3206...
Page 34: ...8 3 Main 1 5 Schematic Diagram L4903SCM1...
Page 35: ...8 4 L4903SCM2 Main 2 5 Schematic Diagram...
Page 36: ...8 5 Main 3 5 Schematic Diagram L4903SCM3...
Page 37: ...8 6 L4903SCM4 Main 4 5 CRT Schematic Diagram...
Page 40: ...8 9 Digital 2 3 Schematic Diagram L4903SCD2...
Page 51: ...12 2 L4905PEX Packing S5 S1 Tape X1 X4 X3 FRONT X2 S2 S2 S3 S3 S8 S7 S4 Packing tape...