Page 3: ...ower 6 Input Voltage and Frequency 6 Power Consumption 6 Power Wiring 6 Signal Wiring 6 External Wiring 6 Power Distribution 7 Signal Distribution 7 Controllers 8 DMX Controller 8 ILUMICON 8 Ilumicode...

Page 4: ...e 17 Product Repairs 17 Troubleshooting Guide 18 Photometrics 19 LED Disclaimer 22 LED Life 22 LED Binning 22 Color Rendering Index CRI 22 Returns Procedure 23 Claims 23 Contact Us 23 Technical Specif...

Page 5: ...rranty Card Quick Reference Guide Unpacking Instructions Immediately upon receiving a product from ILUMINARC carefully unpack the carton Check the contents of the box to ensure that all parts are incl...

Page 6: ...disconnect this product from its power source before servicing Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing when operating b...

Page 7: ...d nuts for cable entry Humidity controlling gore valve Cast aluminum housing ILUMICON compatible Five distinct dimming curves Ilumipod 18 IP Optic VW SpectraWhite Features Operating modes 1 channel Di...

Page 8: ...pod 18 IP Optic Series User Manual Rev 08 Product Overview Mounting Bracket Gore Valve Power In Bracket Adjustment Cable tie location Safety cable attachment Front of product All manuals and user guid...

Page 9: ...Installation Ilumipod 18 IP Optic Series User Manual Rev 08 5 Product Dimensions All manuals and user guides at all guides com...

Page 10: ...of 100 240 VAC 50 60 Hz Power Consumption To determine the power requirements for the Ilumipod 18 IP Optic Series see the label affixed to the side of the product Alternatively you may refer to the co...

Page 11: ...ensure that the corresponding gland nut makes full contact with the cable s external insulation This is required to keep the products IP67 rating when fully adjusted Power Distribution Connect the bar...

Page 12: ...ove controllers are in the Operation chapter of this manual DMX Controller The Ilumipod 18 IP Optic Series can work with a standard DMX controller The channel assignments will depend on the chosen per...

Page 13: ...ode and keep the total distance to less than 60 m 197 ft Otherwise you might need to use an optically isolated signal amplifier Ilumicode The Ilumipod 18 IP uses the Ilumicode addresser for configurat...

Page 14: ...wing the general guidelines below when mounting the Ilumipod 18 IP Optic Series products When selecting an installation location consider ease of access to the product for operation programming adjust...

Page 15: ...ows you which parameters of the Ilumicode controller correspond to the Ilumipod 18 IP Optic Series VW product Main Level Programming Levels Description DMX 001 512 N A Sets the DMX starting address PE...

Page 16: ...C FULL 7 channel RGB control dimmer color macro strobe dimmer speed REMOTE Allows using the ILUMICON unit SOLID 1 channel dimmer CALIB WHITE 1 11 RED GREN BLUE 0 255 Determines the white balance for t...

Page 17: ...respectively Use UP and DOWN to move vertically within the Menu Map options DMX Personality 1 Go to PERSON and select any DMX personality that matches the product with which you are working ignore any...

Page 18: ...COOL or WARM 3 Select a color value 000 255 Color Calibration Only for 18 IP OPTIC RGB 1 Go to CALIB 2 Select a white color WHITE 1 11 or RGBTOW 3 Select an RGB color RED GREN or BLUE 4 Select a colo...

Page 19: ...205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 No Function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red...

Page 20: ...cent Setting 1 Warm White 000 255 0 100 2 Cool White 000 255 0 100 VW D Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Warm White 000 255 0 100 3 Cool White 000 255 0 100 SOLID Channe...

Page 21: ...ticularly dirty surrounding can cause greater accumulation of dirt on the unit s optics To clean a product follow the below recommendations Disconnect the product from power Wait until the product is...

Page 22: ...MX address Change the DMX address Circuit breaker fuse keeps tripping blowing Excessive circuit load Check total load on electrical circuit Short circuit along the power wires Check for a short in the...

Page 23: ...orizontal 0 Vertical 0 Input Wattage 24 6 Luminous Opening Point Test 2009430RGB Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Class Direct Cutoff Class Full Cutoff Flood Summary Effi...

Page 24: ...al 0 Vertical 0 Input Wattage 24 6 Luminous Opening Point Test 2009430RGB Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Class Direct Cutoff Class Full Cutoff Flood Summary Efficiency...

Page 25: ...Luminous Opening Point Test 2009 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Class Direct Cutoff Class Full Cutoff Filename Ilumipod 18 IP Optic 30 VW 100 ALL Flood Summary Eff...

Page 26: ...ated to CRI Results may vary depending on the environmental factors involved For this reason the US Department of Energy DOE states that CRI should be considered as one point of reference among others...

Page 27: ...our phone number The RMA A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility As a sugg...

Page 28: ...25 W 0 4 A 26 W 0 3 A Inrush current 0 3 A 0 3 A Power I O Input Output Connectors Open Wires Open Wires Cord plug Open Wires Open Wires Light Source Type Power Lifespan LED 1 W 50 000 hours Color Qu...

Page 29: ...onsumption 30 W 0 4 A 30 W 0 4 A Inrush current 0 8 A 0 6 A Power I O Input Output Connectors Open Wires Open Wires Cord plug Open Wires Open Wires Light Source Type Power Lifespan LED 1 W 50 000 hour...

Page 30: ...l Information ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 U S A Tel 954 923 3680 www iluminarc com Ilumipod 18 IP Optic Series User Manual Rev 08 August 2011 All manuals and user guides at all gui...