background image

 

 

 

 

Figure 2.  

A single PulseBar can be attached to a controller or in multiple hookups  

 using the HV-1 adapter.

 

 

PulseBar Installation

 

 
For best results, do not block or hinder the flow of ionizing air by placing large objects directly in front 
of or below the PulseBar. 
 
Mount the PulseBar at least 4” above the work surface with its adjustable mounting brackets.  Refer to 
your PulseBar owners manual for details. 
 

Connecting a single PulseBar to the PFC Controller

 

 
Plug the two high-voltage cables from the PulseBar into the two connectors located on the rear panel of 
the PFC. 
 

Connecting two PulseBars to the PFC Controller

 

 
1.   Insert one HV-2 (two-to-one) Adapter into the positive output connector and one into the negative 

output connector located on the back panel of the PFC.  There are two positive and two negative 
positions now available. 

2.   Insert one of the plugs from a PulseBar into one of the positive outputs and the other into one of the 

negative outputs.  Only one positive and one negative output will now be available.

 

3.   Insert the plugs from the second PulseBar the same as the first.  All four output connectors will now 

be used. 

 

NOTE!

 

 

DO NOT

 use an MC-2 adapter if only one PulseBar is in use because arcing or contamination buildup 

may occur. Consult your PulseBar owners manual for further information.

 

Ground connection

 

 

4

Summary of Contents for SIMCO PulseFlow PFC

Page 1: ...CTIONS Operation Maintenance PFC PulseFlow Controller SIMCO s PulseFlow Controller PFC DC pulse and steady state ionizer power supply SECTION 1 Description 2 Specifications 3 Safety Procedures 4 Insta...

Page 2: ...ne Voltage 100 120 230 VAC 50 60 Hz Output Voltage Range 3 5 kv to 8 0 kv D C Pos Neg Output Current Range 3 0 ua to 7 0 ua D C Cycle Pulse Rate Sw Pos Freq Time 10Hz 10Hz 100ms 2 2Hz 2 2Hz 450ms 1 3H...

Page 3: ...power Simco equipment are correctly polarized and grounded Section 4 Installation The PFC can simply be placed on a benchtop or mounted vertically to a wall workbench or machine using the keyhole slo...

Page 4: ...e PFC Connecting two PulseBars to the PFC Controller 1 Insert one HV 2 two to one Adapter into the positive output connector and one into the negative output connector located on the back panel of the...

Page 5: ...ulse mode and will light continuously in the steady state mode 4 Select the desired Pulse Rate by rotating the Pulse Rate switch with a flatblade screwdriver from positions 10hz to 1 0hz Position SS i...

Page 6: ...Front Panel NOTE When the PFC is first turned on one of the lamps will come on and remain on for a few moments This is normal operation After the PFC power supplies stabilize both lamps will start to...

Page 7: ...pton Probable Solution PFC lamps do not flash or turn on at all Check that the unit is plugged in Check the fuses and replace if required The PFC lamps do not flash after a reasonable The Pulse Rate s...

Page 8: ...ential damages except where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or...