Figure 2.
A single PulseBar can be attached to a controller or in multiple hookups
using the HV-1 adapter.
PulseBar Installation
For best results, do not block or hinder the flow of ionizing air by placing large objects directly in front
of or below the PulseBar.
Mount the PulseBar at least 4” above the work surface with its adjustable mounting brackets. Refer to
your PulseBar owners manual for details.
Connecting a single PulseBar to the PFC Controller
Plug the two high-voltage cables from the PulseBar into the two connectors located on the rear panel of
the PFC.
Connecting two PulseBars to the PFC Controller
1. Insert one HV-2 (two-to-one) Adapter into the positive output connector and one into the negative
output connector located on the back panel of the PFC. There are two positive and two negative
positions now available.
2. Insert one of the plugs from a PulseBar into one of the positive outputs and the other into one of the
negative outputs. Only one positive and one negative output will now be available.
3. Insert the plugs from the second PulseBar the same as the first. All four output connectors will now
be used.
NOTE!
DO NOT
use an MC-2 adapter if only one PulseBar is in use because arcing or contamination buildup
may occur. Consult your PulseBar owners manual for further information.
Ground connection
4
Summary of Contents for SIMCO PulseFlow PFC
Page 9: ...9...