10
ELECTRICAL WIRING
OPERA
Your licensed electrician is responsible for providing all electrical components and making
all necessary connections from the motor to the appropriate power source.
All Washdown Rated Stainless Steel Fans come with a wiring schematic, usually printed on
the nameplate of the motor. Fans must be wired exactly as shown. This is a dual voltage
motor, take care to select the correct wiring configuration based on your voltage level.
Warning:
Improper wiring can damage motors, cause injury, and affect warranty coverage.
It is highly recommended that all fans have an independent disconnect switch located
within visual sight of the fan. This switch should be used in conjunction with all “lock out,
tag out” procedures during service and maintenance.
ELECTRICAL INSTALLATION
(Power cord not included)
1. Remove the 4 screws from the Junction Box. Open the Junction Box Cover.
2. Unscrew the Thread-Lock Sealing Nut.
3. Thread the appropriate power cord through the Thread-Lock Sealing Nut and Cable
Gland body in turn.
(
Power cord not included
)
4. Follow the wiring diagram (Figure 2: 115V/60Hz, Figure 3: 230V/60Hz and
table1:Plug and socket) for proper connections.
5. Tighten the Thread-Lock Sealing Nut.
Thread-Lock Sealing Nut tightening requirements: No movement of the power cord
under a maximum tension of 36 LBS.
6. Install the junction box cover:
CAUTION:Make sure the sealing ring is in the
original position after installation.
Installation standard Requirements: Screws are tightened with a torque of 2.4NM.