background image

3

Fans are UL/CUL Listed, Standard 705.

1. Do not depend on any switch as the sole means of disconnecting

power when installing or servicing the fan.

2. Always disconnect, lock-out, and tag-out power source before installing

or servicing. Failure to disconnect power source can result in fire, shock,

or serious injury.

3. Motor will restart without warning after thermal protector trips. Do not

touch operating motor; it may be hot enough to cause injury.

4. Do not place body parts or objects in fan or motor openings while motor

is connected to the power source.

5. All electrical connections should be made by a qualified electrician.

6. These utility exhaust fans are for general purpose exhaust applications

only. Do not use these exhaust fans in an area where corrosive or

explosive materials may be found.

7. Follow all local and state/provincial electrical and safety codes in the

United States and Canada, as well as the National Electrical Code (NEC)

and the Occupational Safety and Health Act (OSHA) in the United States,

and the Canadian Electric Code (CEC) in Canada.

8. Always disconnect power source before working on or near a motor or its

connected load.

9. Protect the power cable from coming in contact with sharp objects.

10. Do not kink or create tight bends in the power cable and never allow the

cable to come in contact with oil, grease, hot surfaces, or chemicals.

11. Make certain that the power source conforms to the requirements of

your specific exhaust fan model. The fan frame and motor must be

electrically grounded to a suitable electrical ground, such as a grounded

water pipe or ground wire system.

12. To reduce the risk of injury to persons, please observe the following:

In the United States, OSHA compliant guards are required when fan is

installed within 7 feet of the floor or working level. In Canada, CSA

compliant guards are required when fan is installed below 2.5 meters

(8.2 feet) above the floor or grade level.

13. Questions? Please contact our service center by calling 1-800-317-

1688.

GENERAL SAFETY INSTRUCTIONS

Summary of Contents for ILG8SF10V

Page 1: ...1 SHUTTER MOUNTED EXHAUST FAN Models ILG8SF7V ILG8SF10V ILG8SF12V ILG8SF16V ILG8SF18V ILG8SF18S ILG8SF20V ILG8SF24V ILG8SF30S ILG8SF36S OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...voltage prior to final electrical connection Please refer to the motor s nameplate label Wiring must conform to local state and national codes Tools Materials Needed Mounting Fasteners 8 Sealant or C...

Page 3: ...he National Electrical Code NEC and the Occupational Safety and Health Act OSHA in the United States and the Canadian Electric Code CEC in Canada 8 Always disconnect power source before working on or...

Page 4: ...ch as thermostats switches or speed controls 3 Connect power to the motor using an approved wiring method Refer to the following wiring diagrams Figure 1 Figure 2 Fan frame and motor must be securely...

Page 5: ...5 Figure 2 Wiring Diagram Single speed 115 volt connection for ILG8SF18S ILG8SF30S ILG8SF36S...

Page 6: ...2 ILG8SF12V 12 15 15 5 3 4 2 6 5 32 13 5 8 12 1 8 12 1 8 8 3 1 2 9 32 1 2 13 ILG8SF16V 16 18 29 32 18 29 32 5 3 4 2 7 7 8 17 3 4 16 16 11 29 32 3 17 32 9 32 1 2 17 ILG8SF18V 18 21 21 5 3 4 2 8 3 4 19...

Page 7: ...4 2 75 1075 Ball 6 67 3368 2312 1868 ILG8SF24V 24 1 4 2 75 1075 Ball 7 4244 2676 2220 ILG8SF30S 30 1 3 3 30 825 Ball 7 01 5088 3432 1552 ILG8SF36S 36 1 2 6 00 825 Ball 8 24 6128 4380 2620 1 Keep the a...

Page 8: ...tor bearings as per instructions or replace motor Loose propeller Tighten set screws on propeller hub Bent or damaged propeller Replace propeller Loose guard assembly or motor fasteners Tighten as req...

Page 9: ...omer review Please visit https www amazon com review review your purchases At iLiving USA we are committed to bringing top quality products to our customers iLIVING USA 860 Mahler Road Burlingame CA 9...

Reviews: