Fans are UL/cUL Listed, Standard 705. 

1. Do not depend on any switch as the sole means of disconnecting     

power when installing or servicing the fan.  

2. Always disconnect, lock-out, and tag-out power source before installing 

or servicing. Failure to disconnect power source can result in fire, shock, 
or serious injury. 

3. Motor will restart without warning after thermal protector trips. Do not 

touch operating motor; it may be hot enough to cause injury. 

4. Do not place body parts or objects in fan or motor openings while motor 

is connected to the power source.  

5. All electrical connections should be made by a qualified electrician.                                   
6. These utility exhaust fans are for general purpose exhaust applications 

only. Do not use these exhaust fans in an area where corrosive or 
explosive materials may be found. 

7. Follow all local and state/provincial electrical and safety codes in the 

United States and Canada, as well as the National Electrical Code (NEC) 
and the Occupational Safety and Health Act (OSHA) in the United States, 
and the Canadian Electric Code (CEC) in Canada. 

8. Always disconnect power source before working on or near a motor or its 

connected load. 

9. Protect the power cable from coming in contact with sharp objects. 
10. Do not kink or create tight bends in the power cable and never allow the 

cable to come in contact with oil, grease, hot surfaces, or chemicals. 

11. Make certain that the power source conforms to the requirements of 

your specific exhaust fan model. The fan frame and motor must be 
electrically grounded to a suitable electrical ground, such as a grounded 
water pipe or ground wire system. 

12. To reduce the risk of injury to persons, please observe the following:  
   In the United States, OSHA compliant guards are required when fan is 

installed within 7 feet of the floor or working level. In Canada, CSA 
compliant guards are required when fan is installed below 2.5 meters 
(8.2 feet) above the floor or grade level. 

13. Questions? Please contact our service center by calling 1-800-317-

1688. 

 
 
 
 

GENERAL SAFETY INSTRUCTIONS

 

Summary of Contents for ILG8SF10V(APB-10A)

Page 1: ...AN Models ILG8SF10V APB 10A ILG8SF12V APB 12A ILG8SF16V APB 16A ILG8SF18V APB 18A ILG8SF18S APB 18B ILG8SF20V APB 20A ILG8SF24V APB 24A ILG8SF30S APB 30B ILG8SF36S APB 36B OWNER S MANUAL PLEASE READ A...

Page 2: ...LL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR Installation troubleshooting and replacement are to be performe...

Page 3: ...he National Electrical Code NEC and the Occupational Safety and Health Act OSHA in the United States and the Canadian Electric Code CEC in Canada 8 Always disconnect power source before working on or...

Page 4: ...or move will result in excess vibrations which may cause possible premature motor propeller or 2 Install any auxiliary components such as thermostats switches or speed ect power to the motor using an...

Page 5: ...5 Figure 2 Wiring Diagram Single speed 115 volt connection for ILG8SF18S APB 18B ILG8SF30S APB 30B ILG8SF36S APB 36B...

Page 6: ...B 10A ILG8SF12V APB 12A ILG8SF16V APB 16A ILG8SF18V APB 18A ILF8SF18S APB 18B Prop Dia 10 12 16 18 18 A 13 15 18 29 32 21 21 B 13 15 18 29 32 21 21 C 4 17 32 5 3 4 5 3 4 5 3 4 5 3 4 D 2 2 2 2 2 E 5 7...

Page 7: ...9 32 9 32 9 32 I 1 2 1 2 1 2 1 2 Suggested Wall Opening Sq 21 25 31 37 Model Prop Dia Nom HP Amps Nom RPM Bearing Type Sones 0 0 SP 5 CFM Air Delivery Static Pressure Shown 0 00 0 125 0 25 ILG8SF10V...

Page 8: ...h air intake on the opposite side of the area to be the shutter will open automatically When the unit is turned OFF the shutter will close 4 Speed controllable units are designed to operate at a minim...

Page 9: ...Replace fuse or reset circuit breaker Defective motor Replace motor Switch in OFF position Turn switch ON Blocked intake or exhaust opening Clear intake and exhaust openings of any obstructions Clean...

Page 10: ...10...