1
USER MANUAL
For
ALM-0808/1608/1616 alarm controller
1.
Introduction
The alarm controller is designed to work with PC based DVR (Hybrid DVR Server) and analog matrix
system. In fact there is no hardware device of ALM-3232. It is only a kind of software name. You can
combine 2 pieces of ALM-1616 to build up ALM-3232 via first device ID=1 and second device ID=2.
1.1
Input port
(
16 ports input for ILDVR-1608, 8 ports input for ILDVR-0808
)
IN – Sensor Data + I-COM – Sensor Data -
ID – Device ID (Alarm controller address) CODE – RS485 port
DC12V – 12V DC Power ALARMS-IN indicator – Flashes when connects a sensor
1.2
Output port.
NO – Normal Open connecter C – COM connecter
NC – Normal Close connecter ALARMS OUT indicator – Flashes when there is an alarm
1.3
Specifications
Power Supply:
ALM-0808 is DC12V/8W, ALM-1608 is DC12V/12W, ALM-1616 is AC220V/10W or
AC110V/ 10W
DI Port:
N/C or N/O
DO Port:
N/C or N/O
Output:
10A/DC28V or 7A/AC220V
Working Temperature:
-10
℃
- 55
℃
Humidity:
≤
90% RH
Dimension:
ALM-0808/1608 is 182×120×30mm, ALM-1616 is 484×300×15.5mm