background image

 

USER MANUAL 

For 

  ALM-0808/1608/1616 alarm controller 

 

1.

 

Introduction 

The  alarm controller is designed to work with PC based DVR (Hybrid DVR Server) and analog matrix 

system.  In fact there is no hardware device of ALM-3232. It is only a kind of software name.  You can 

combine 2 pieces of ALM-1616 to build up ALM-3232 via first device ID=1 and second device ID=2. 

 

1.1

 

Input port 

16 ports input for ILDVR-1608, 8 ports input for ILDVR-0808

 

 

IN – Sensor Data +                         I-COM – Sensor Data -   

ID – Device ID (Alarm controller address)      CODE – RS485 port 

DC12V – 12V DC Power                   ALARMS-IN indicator – Flashes when connects a sensor 

 

1.2

 

Output port. 

 

 

NO – Normal Open connecter         C – COM connecter 

NC – Normal Close connecter         ALARMS OUT indicator – Flashes when there is an alarm 

 

1.3

 

Specifications 

 

Power Supply:

  ALM-0808 is DC12V/8W, ALM-1608 is DC12V/12W, ALM-1616 is AC220V/10W or 

AC110V/ 10W 

DI Port:

 N/C or N/O   

DO Port: 

N/C or N/O 

Output: 

10A/DC28V or 7A/AC220V 

Working Temperature: 

-10

 

- 55

 

Humidity: 

90% RH

 

Dimension: 

ALM-0808/1608 is 182×120×30mm, ALM-1616 is 484×300×15.5mm 

Reviews: