11
Basic installation and configuration
/IKUNET bus configuration
7)
In the home page of the selected module,
“Admin” appears by default in the
USer
field.
Enter the word “admin” in the
paSSword
field
and click on
aCCept
.
8)
The main management window for the STC-100
module as slave module is displayed.
NoTE
The module with which you have con-
nected the PC disconnects automatically
after 15 minutes without interaction.
9)
In the main menu, click on Master
modUle >
ConfigUration
. The
general SyStem parameterS ConfigUration
window is displayed, with the
inStallation data
tab.
10)
Enter the name of the module in the
modUle
name
field.
NoTE
IKUSI recommends you give a description
to the module according to its position
in the headend in order to identify the
modules logically and physically. For
example, for a configuration identical to
that proposed in the assembly section, in-
clude the following identifications (on the
base, from right to left:
StC-1 maSter,
StC-2
).
11)
To activate the module as master of the head-
end, click on the
thiS StC-100 iS the maSter modUle
checkbox. The module
will be configured as master once the window has been saved.
CAUTIoN
If the background of the field is red, this means that the data has been modi-
fied but has not yet been saved. Before changing to another window or tab, any
modified data must be saved (click on
Save
). Otherwise, the modified data will
be lost and the previous information state will be maintained in the headend.
NoTE
If the IKUNET bus is connected to another Ethernet bus, we recommend you limit
the IP range to the number of slave modules in the IKUNET bus, so that these
can be identified more easily.
12)
Click on
exit
in the main screen (top right corner).
EN