background image

The troubleshooti ng LEDs are located on the receiver board. In order to reach the signalling, the receiver must be          

accesible and connected and the two screws located on the base of the receiver must be released, using the suitable 

tool. 

LED

LED COLOUR / 

FREQUENCY 

PULSE 

FREQUENCY

MEANING

ACTION

POWER

Green / 

Conti nuous

Switched ON if powered.

Check power supply if 

it is switched OFF

STATUS

Blue / 

Fast pulses

Starti ng the system, stablishing commu-

nicati on with radio and EEPROM.

Wait

Blue/ 

Conti nuous

Waiti ng for tranmistt er communicati on. 

Coming from ACTIVE STOP.

Release STOP pushbut-

ton and press START

Blue/ 

Slow pulses

Waiti ng for tranmistt er communicati on. 

Coming from PASIVE STOP.

Press START

Green / 

Conti nuous

Working.

Operate

Red / 

Slow pulses

EEPROM Error. EEPROM module mising 

or corrupt.

Check EEPROM and 

reprogram if necessary 

Red / 

Double pulses

Radio Errror. Radio communicati on error. Replace receiver

Red / 

Triple pulses

Secondary micro error or error between 

micro communicati on.

Replace receiver


DIAG 1

Red/ 

4 pulses
Orange/

Slow pulses

Low tension in the receivers power 

supply

Supply the system with 

the correct voltage

Red/ 

4 pulses
Orange/

Double pulses

Hardware error

Replace receiver

Red/ 

4 pulses
Orange/

Triple pulses
Red/ 

4 pulses
Orange/ 

4 pulses

DIAG 1

Green / 

Slow pulses

Low 

link quality

Green / 

Double pulses

Medium 

link quality

Green / 

Triple pulses

High 

link quality

ORDER

Green / 

Conti nuous

RELAY

Green / 

Conti nuous

STOP relay acti vated

04- TROUBLESHOOTING

04- TROUBLESHOOTING

LEDs on the receiver board.

POWER STATUS DIAG1

DIAG2 ORDER RELAY

Summary of Contents for R11

Page 1: ...R11 USER s MANUAL Paseo Miramón 170 20014 Donostia San Sebastián Guipúzcoa Spain tlc ikusi com ...

Page 2: ...ke sure the transmitter you are going to use is the right one Identify the machine controlled on the label for this purpose on the transmitter or by using the display in case it has one j Service the equipment periodically k When carrying out repairs only use spare parts supplied by IKUSI dealers WARNING The equipment must be operated by qualified personnel After use never leave the equipment ON on...

Page 3: ...e ISED radio frequency RF Exposure rules This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Le présent appareil est conforme à l exposition aux radiations FCC ISED définies pour un environnement non contrôlé et répond aux directives d exposition de la fréquence de la FCC radiofréquence RF et RSS 102 de la fréquence radio RF ISED règles d exposi...

Page 4: ...CAN ICES 3 B NMB 3 B This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de classe B est conforme à la norme canadienne ICES 003 ...

Page 5: ... 02 30 30 60 1 Fixing slots fixed assembly or anti vibration or anti vibration with magnets 2 M32 Cable Gland 3 Power Supply 4 LR11 logic board 5 Removable EEPROM 6 Signalling LEDs 7 2 4 GHz Radio 8 Wiring connection The use of the antivibration kit is recommended in any case 1 2 8 5 4 3 7 6 ...

Page 6: ...t A 8 A Maximun voltage V AC 250 V Analogue Outputs Max na CANOpen Profibus DP SAE J1939 na ON OFF Inputs Max na Analogue Inputs Max na STOP FUNCTION Performance Level EN 13849 Category 3 PL d Maximum output current A 6 A Output voltage V AC 250 V Temperature range 20ºC 70ºC Relative Humidity Máx 95 without condensation Storage temperatura range 24h 25ºC 75ºC 13F 167ºF Storage temperatura range lo...

Page 7: ... location if possible with a direct vision between the receiver s antenna and the transmitter s working area 2 In cases where a high level of vibration is expected it is recommended the use of shock absorvers It can be supplied as an accessory a magnet kit which allow a esay and fast assembly and the shock absorver kit 3 Proceed the connection of the power supply and the receiver s outputs Use the...

Page 8: ... STOP Press START Green Continuous Working Operate Red Slow pulses EEPROM Error EEPROM module mising or corrupt Check EEPROM and reprogram if necessary Red Double pulses Radio Errror Radio communication error Replace receiver Red Triple pulses Secondary micro error or error between micro communication Replace receiver STATUS DIAG 1 Red 4 pulses Orange Slow pulses Low tension in the receivers power...