8
GB
| Operating Instructions
Warning: Switch off and remove plug from mains before investigating fault.
Symptom
Possible
Remedy
Machine fails to operate
Power turned off
Turn power on
Mains socket faulty
Use another socket
Extension cable damaged
Inspect cable, replace if damaged.
Fuse faulty/blown
Replace fuse
Mower in long grass
Increase height of cut and tilt mower
Motor protector has activated
Allow to cool for a few minutes and
increase height of cut
At this time do not operate the switch
lever 1 as this will prolong the reset
time of the safety cut out
Machine functions
intermittently
Extension cable damaged
Inspect cable, replace if damaged.
Machines internal wiring damaged
Contact your service agent.
Motor protector has activated
Allow to cool for a few minutes and
increase height of cut.
At this time do not operate the switch
lever 1 as this will prolong the reset
time of the safety cut out.
Machine leaves lagged finish of
motor labours
Height of cut too low
Increase height of cut (see height of
Cut Adjustment)
Cutting blade blunt
Replace blade (see Blade Mainte-
nance)
Underside of machine badly clogged
Clean machine (see After Mowing/
Storage)
Blade fitted upside down
Refit blade correctly (see Blade
Maintenance)
Cutting blade not rotating
Cutting blade obstructed
Clear obstruction
Blade nut/bolt loose.
Tighten blade nut/bolt
Excessive vibration/noise
Blade nut/bolt loose.
Tighten blade nut/bolt
Cutting blade damaged
Replace blade
Fault Finding
The following table gives checks and actions that you can perform if you machine does not operate correctly. If these
do not identify/remedy the problem, contact your Service Agent.