EN // 89
USER’S MANUAL
EN
Er03 / No flames or
insufficient pellets
Fumes temperature
under 55°C (Th03).
Empty pellet tank;
damaged thermopair;
pellet feeder tube
blocked.
Refuel the
pellet tank; call
assistance.
Er05 / High fumes
temperature
Fumes temperature
over 300°C.
Ambient ventilator not
working or in a low
power level; insuficient
fumes flow; execessive
pellet dosage; fumes
temperature probe
damaged.
Increase the power
level to maximum
(if the problem
persists, call
assistance).
Er07 / Fumes extractor
error
No RPM signal; allows
to unlock and work by
tension temporarely
P25=0.
Check connection; check if ventilator is
blocked; after correction of this malfunction,
select P25=2 (default value).
Er08 / Fumes extractor
encoder error
Comunication with
the encoder but the
regulation of the fumes
has failed P25=0.
Exaust tube or extrator
damaged.
After correction of
this malfunction,
select P25=2
(default value).
Er12 / Ignition failure
Max time of 900s and
fumes temperature
below 50°C.
Empty pellet feeder
screw; ignitor damaged;
burner not placed
correctly; fumes
temperature did not
reach 50°C.
Try to start again;
replace the ignitor.
Er15 / Out of power
supply
Not connected to power
supply for more than 50
min.
Check the electricity tension; check for more
apliances connected at the same time; in case
of out of power supply for a short period of time
(<10s) the stove keeps working normally; if the
system was in “On” mode and the period out of
power supply is between 10s and 50min, the
stove make an ignition after blackout.
Er16 / Fail in
comunication with
LCD display
–
Check connection between display and
motherboard.
Er39 / Differencial
pressure sensor
damaged
The fuel regulation is
interrrupted and the
stove will work with the
standard factory values
and enter “stand by”
mode until the fumes
temperatures drops
bellow <85°C (Th28).
Check the connection between the
motherboard and the diferencial pressure
sensor; check the reading of the sensor; check
for blockage in the sensor air measure intakes.
Er41 / Minimum value
/ reference for the
diferencial pressure
sensor not reached in
the checkup stage
Value of 70 not reached
(FL20). The regulation
is canceled and the
stove enters in shut
down mode.
Check the connection between the
motherboard and the diferencial pressure
sensor; check for blockage in the sensor air
measure intakes or silicon tubes.
Er42 / Maximum value
/ reference for the
diferencial pressure
sensor reached
The regulation is
canceled and the stove
enters in shut down
mode.
Check the connection between the
motherboard and the diferencial pressure
sensor; check for blockage in the sensor air
measure intakes or silicon tubes.
Summary of Contents for ECOpellets 8
Page 2: ......
Page 4: ......
Page 5: ...PORTUGU S MANUAL DO UTILIZADOR...
Page 36: ...ESPA OL MANUAL DEL USUARIO...
Page 67: ...ENGLISH USER S MANUAL...
Page 98: ...NOTAS NOTES...
Page 99: ......