IKL GULIVER TERMO User Manual Download Page 6

3. INSTALATION

Picture.1

1. Top plate frame

11. Side 
decoration

21. Handle for 
shaking of embers

2. Top plate

12. Back 
batten

22. Fire door

3. Burner

13. Stand 
frame

23. Door handle

4. Smoke exaust

14. Front 
batten

24. Regulation of 
secondary air

5. Handle gas flow 
regulator

15. Oven 
door

25. Cauldron

6. Decorative top 
plate

16. 
Decorative 
botom plate

26. Decorative 
gallery

7. Back side

17. Screws of 
decorative 
plate

27. Cover of the 
smoke exaust from 
the top side

8. Cover of the smoke
exaust from the back 
side

18. Drawer

28. Regulation 
button of draft

9. Small side 
decoration

19. Ashtray 
door

10. Regulation of 

draft

20. 

Regulation of

primary air

Stove is connected to the chimney flue pipe appropriate, to ensure adequate tightness

and  flow  of  smoke  from  the  stove  to  chimney  .Flue  pipe  must  not  be  too  deep  in  the

chimney so it would not reduce the area of cross section and thus violated the drafts in the

chimney.

Stove allows revolusion of the flue gases from the top (item 4) or last (item 8) over the

side of the stove, through respective ranges of ports that are on opposite side of the side of

fireplace.Standard stove parts are connection to flue pipe and the cover of smoke.

Standard cover is set on the back side, a connector for connecting the flue pipe is in the

drawer, and  if  the  user wants that the smoke  exaust  is from above, it  is necessary  to fix

the  connection  to  the  required  space.  Way  of  tying  the  cover  and  the  connector  is  with

screws.

Summary of Contents for GULIVER TERMO

Page 1: ...1 Model GULIVER TERMO USER MANUAL IKL INDUSTRIJSKI KOMBINAT LIVNICA DOO GU A Srbija 32230 Gu a Albanske spomenice bb Tel centrala 381 0 32 306 000 prodaja i servis 381 0 32 854 305...

Page 2: ...ossibilities before first operating it and keep them for future reference to ensure avoiding irregularities in your stove s operation Yours sincerely GU A CONTENTS 1 Introductory notes 2 Technical dat...

Page 3: ...or should be opened only to add fuel Open door gradually to equalise internal pressure Opening the doors suddenly may cause flame and smoke to escape outside Fuel should be added only when glowing emb...

Page 4: ......

Page 5: ...bar 2 Rated output kg h 3 6 Boiler capacity l 15 Efficiency 88 Flue pipe diameter mm 120 150 Heat capacity m3 190 250 The mean content of CO at 13 O2 0 1007 Weight kg 190kg Firebox opening size width...

Page 6: ...primary air Stove is connected to the chimney flue pipe appropriate to ensure adequate tightness and flow of smoke from the stove to chimney Flue pipe must not be too deep in the chimney so it would...

Page 7: ...ended for heating of residential premises and food preparation For water supply and drainage into the system of storey central heating is provided with the connections on the boiler 1 Storey stove can...

Page 8: ...highest radiator Note The installation and commissioning of the entire system should be entrusted only technician who ensures proper operation of the entire heating system In the case of poorly design...

Page 9: ...Picture 4 Schemeofclosedsystem...

Page 10: ...Picture 5 Schemeofclosedsystem...

Page 11: ...Picture 6 Schemeofopensystem...

Page 12: ...ught in the flue the chimney must be rising at least one metre above the ridge of the roof The chimney must not be covered by surrounding objects Picture 4 Picture 4 The dimensions of the chimney may...

Page 13: ...gulator into the open position open the hearth door put the necessary fuel into the hearth ungreased paper small pieces of wood Ignition is performed The hearth and ashtray door is closed After the in...

Page 14: ...the exit of smoke and flame from the hearth The hearth door must be closed when the stove is used Picture 8 The wood should have maximum 20 humidity In addition to bad combustion effect wet wood leav...

Page 15: ...mary air regulator position 20 is set in the closed position and it should be kept in this position at all times of work of the stove When closed the regulator prevents air intake from the front side...

Page 16: ...glass surface After cleaning rinse with pure water and dry The additional equipment that is delivered with the stove is the glove and equipment for shaking of embers and removal of ashtray picture13 P...

Page 17: ...tor for primary air Frame of the top plate all doors grill furnace linings grill smoke exhaust port and galleries cariers were made of gray cast iron On the oven door and fireplace is the glass temper...

Page 18: ...equately Check whether the chimney dimensions are correct and suitable for the device Check the thermic insulation of the chimney and if it is made according to standard The hearth door must be closed...

Page 19: ...ove loses the right for the service provided by the manufacturer s warranty The supply of spare parts is performed exclusively through the factory service based on the positions and pictures in this i...

Page 20: ......

Page 21: ......

Reviews: