4.  

Carefully open the housing back. 

Installing the Camera

1.  

Remove any lanyard, neck strap, or accessory attached 

to the camera.

2.  

Place the camera into the front of the housing with the 

lens centered in the lens port. 

3.  

Make sure the camera is sitting flat in the housing and 

flush to the front support ribs. 

Closing the Housing

1.  

Apply a very thin, even layer of lubricant to the exposed 

portion of the o-ring and housing sealing surface. Avoid 
dry spots or uneven build-up of lubricant.

2.  

Close and latch the housing back. Press the latch 

towards the housing until the lock buttons click into place.

3.  

Check the latch. The buttons will not be depressed when 

the latch is properly locked. Pulling on the latch without 
pressing the buttons should not allow the latch to open.

Maintenance

Post-Dive

1.  

Rinse the housing in fresh water. Rotate the housing 

controls and press each button while submerged in fresh 
water to flush out any salt or debris to ensure smooth 
operation on future dives.

2.  

NEVER leave your housing in the fresh water rinse tank. 

Collisions with other peoples’ gear can cause scratches or 
damage to your equipment. 

3.  

Store the housing in a shaded place where it is protected 

from impact or overheating. If no shade is available, we 
recommend covering the housing with a towel or cloth. 

Travel and Storage

1.  

Remove the camera from the housing for travel or 

storage.

2.  

Check and lubricate the main housing o-ring.

Support rib

3.  

Close the empty housing and submerge in lukewarm 

fresh water. While submerged, rotate each control and 
depress each button to flush out any salt or debris.

4.  

Remove the housing from water and rinse with running 

water.

5.  

Do not rinse the inside of the housing or submerge the 

open housing in water. If the inside of the housing needs 
to be cleaned, wipe with a clean, slightly damp cloth.

6.  

Dry the housing with a clean, lint-free cloth.

7.  

Store in a cool, dry place.

8.  

Like regulators and other pressure-sensitive equipment, 

we recommend careful cleaning along with annual 
replacement of the factory seals.

Limited Warranty

This Ikelite product is warranted against any manufacturing 
defects for a period of two (2) years from the original date 
of purchase. To obtain warranty service, the product must 
be returned to Ikelite postage paid. Ikelite will, at its sole 
discretion, repair or replace such products, and will return 
to customer postage paid. All other claims of any nature are 
not covered. Except as mentioned above, no other warranty 
expressed or implied applies to this Ikelite product.

Contact Us

Ikelite Underwater Systems 
50 W 33rd St
Indianapolis, IN 46208 USA 
(317) 923-4523 
[email protected]

Product Registration

Please register your product within 15 days of purchase. Our 
product registration database is the quickest way for us to 
contact you in the event of a product update.
To register, send a photo of the above registration label to us 
via [email protected] along with your name, address, and 
phone number.

Reviews: