background image

15

PPrree--D

Diivvee YYoouurr SSyysstteem

m

It is recommended that you take the complete system into a

swimming pool before use in open water. This will give you a

chance to become familiar with the handling and operation of

your housing and strobe(s).

O

Oppttiioonnaall AAcccceessssoorriieess

LLeeaadd W

Weeiigghhtt ##00990066..5588

The buoyancy of the system will depend on the size and

number of strobes used as well as the weight of the camera.

Ideally the system should be slightly negative in the

environment in which it will be used. If you need to add weight

to the system, an optional lead weight is available. To add the

lead weight remove the (2) screws from the bottom of the

aluminum tray. Place the lead weight into the pocket of the

aluminum tray and reattach.

IIkkeelliittee LLuubbee ##00118844..11
PPoorrtt O

O’’rriinngg ##00110055

H

Hoouussiinngg BBaacckk O

O’’rriinngg ##00113322..5599

While both the Port and Back o’rings should last quite some time

it is best to carry a spare in case one becomes damaged or lost.

SSttoorriinngg tthhee H

Hoouussiinngg

When the housing is going to be stored for a prolonged period it

should be soaked in a mild soap solution, rinsed and dried

thoroughly. Remove the back and port from the housing.

Remove the back and port o’rings, lightly lubricate them and

place them in a plastic zip-lock bag. Place the plastic bag inside

the housing for storage. Operate the push buttons periodically.

16

CChhoooossiinngg aa PPoorrtt

D

DO

OM

MEE PPO

ORRTT

#5503 ........Wide angle 28mm to 17mm

or lens up to 7.6cm (3") in length

#5503.20 ..Nikon 18 & 20mmD lenses

#5503.50 ..Lens 7.6-10.1cm (3-4")

#5503.55....Lens 8.9-11.4cm (3.5-4.5")

#5503.80 ..Lens 10.1-12.7cm (4-5")

#5503.81....Nikkor 28-105mm lens only

#5503.85 ..Lens 12.7-15.2cm (5-6")

Some zoom lenses may require the addition of a +diopter close-up lens. 

(Available from camera store).

SUPERWIDE DOME PORT

Superwide lens 110° to 170°. Not compatible with the SLR-MD housing due

to vignetting.

#5503.15 ........Lens up to 6.3cm (2.5")

•With the lens on the camera extended to

full length, measure from front of camera

to face of lens.

•Select the appropriate port based on the

lens type and length.

•Maximum lens diameter accommodated is

8.4cm (3.3")

•Maximum lens diameter when using

zoom or focus clamp 7.1cm (2.8")

Measure

PPoorrtt IInnffoorrm

maattiioonn

While we have included a list of our ports and a short list of Canon

Lenses and port recommendations we suggest visiting our web site

for the latest information on lenses and port recommendations.

14

SSttrroobbee AArrm

mss

This housing offers two types of arm mounting systems. The

top of the rubber handles utilize Ikelite’s Quick-Release Arm,

available with the SA-100R Arm system. 

The bottom of the rubber handles have a wing nut that accepts

the Ikelite Tray Mount. The Tray Mount comes with the Ikelite

SA-125 Arm system and the SA-100T Arm system.

13

U

Ussiinngg EExxtteerrnnaall SSttrroobbeess CCoonntt..
U

Ussiinngg IIkkeelliittee N

Noonn--D

DSS SSuubbssttrroobbeess ((SSuubbssttrroobbee 5500,, 110000AA,,

220000,, 440000)) w

wiitthh tthhiiss H

Hoouussiinngg..

The Conversion Circuitry is automatically disabled when used

with a Non-DS Substrobe. These Substrobes can be used in their

manual mode utilizing any power settings provided on the

Substrobe.

U

Ussiinngg N

Noonn IIkkeelliittee SSttrroobbeess w

wiitthh tthhiiss H

Hoouussiinngg..

The Conversion Circuitry is automatically disabled when used

with a Non Ikelite Strobe. These strobes can be used in their

manual mode utilizing any power settings provided on the strobe.

Summary of Contents for 6871.2

Page 1: ...ubricant to lightly cover control shafts and o rings Wipe off any excess lubricant with a clean cloth Lubricant is not a sealant it is used to reduce friction Excessive lubricant can collect sand and dirt which may interfere with proper sealing C CA AU UT TI IO ON N N Ne ev ve er r u us se e s sp pr ra ay y l lu ub br ri ic ca an nt ts s a as s t th he e p pr ro op pe el ll la an nt t i in ng gr r...

Page 2: ...ce down in your lap 2 Check to see that there is an o ring on the housing back and that it is clean and in its proper location 3 Guide the back onto the housing The o ring should touch the housing all the way around There should be an even gap all the way around between the housing and the housing back 4 Lift the lid snaps so they are extended and place the lid snap into the hook on the housing ba...

Page 3: ...lected the Red LED directly below the F full power will illuminate Note that the Manual minus compensation values are in the black bar with the heading M S Se et t D DS S S Su ub bs st tr rb bo oe e t to o T TT TL L m mo od de e F 1 2 3 M MODE 2 1 1 2 TTL Red LEDs Compensation Mode Compensation Buttons Manual Mode Yellow LED TTL Mode Yellow LED 3 3 U Us si in ng g E Ex xt te er rn na al l S St tr ...

Page 4: ... 1 12 7cm 4 5 5503 81 Nikkor 28 105mm lens only 5503 85 Lens 12 7 15 2cm 5 6 Some zoom lenses may require the addition of a diopter close up lens Available from camera store SUPERWIDE DOME PORT Superwide lens 110 to 170 Not compatible with the SLR MD housing due to vignetting 5503 15 Lens up to 6 3cm 2 5 With the lens on the camera extended to full length measure from front of camera to face of le...

Page 5: ... 2 17 40mm USM 5503 50 2 18 55 EF S 5503 20 35mm 5503 50 20 35 Ultrasonic 5503 2 22 55 Ultrasonic 5503 50 2 24 85mm 5503 50 28 70mm 5503 85 3 28 80mm 5503 50 28 80mm USM 5503 50 2 28 105mm EF USM II 5503 55 2 28 105mm USM 5503 80 2 35 80mm 5503 5502 35 135mm 5503 80 S Si ig gm ma a A AF F C Ca an no on n D Do om me e F Fl la at t P Po or rt t 28 105mm f 2 8 4 5503 80 2 Zoom lenses that do not focu...

Page 6: ...move the strobe closer or farther away to properly expose the subject with the chosen camera aperture 21 3 Some of the controls have a short shaft and cannot be pulled out exposing the shaft for lubrication In the unlikely event one of these controls sticks or becomes difficult to operate you can remove the control from the housing and lubricate it or return the housing to Ikelite for maintenance ...

Reviews: